UHT Aseptic Dairy Processing & Filling

Product family: 1L UHT Aseptic Bricks.

Flow: Dairy Co-op & Carton Supplier → Reception & Standardization → Homogenize & Cream Balance → UHT Sterilizer & CIP Cycles → Aseptic Brick Filling → Tray Wrap & Cold Store → Supermarket Regional Hubs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: UHT Aseptic Dairy Processing & FillingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Dairy Co-op & Carton Supplier → Reception & Standardization (4.5 s) → Homogenize & Cream Balance (5.4 s) → UHT Sterilizer & CIP Cycles (7.2 s) → Aseptic Brick Filling (5.7 s) → Tray Wrap & Cold Store (4.2 s) → Supermarket Regional Hubs.SUPPLIERDairy Co-op &Carton SupplierI1.20 d1Reception &StandardizationC/T 4.5 sI1.10 d2Homogenize &Cream BalanceC/T 5.4 sI1.50 d3UHT Sterilizer &CIP CyclesC/T 7.2 sI0.90 d4Aseptic BrickFillingC/T 5.7 sI1.10 d5Tray Wrap & ColdStoreC/T 4.2 sI1.40 dCUSTOMERSupermarketRegional Hubs8,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Reception & Standardization4.5 s25 min95%99.1%8,0009,600 (1.20 d)10,984
2. Homogenize & Cream Balance5.4 s35 min92%98.4%6,4008,800 (1.10 d)8,613
3. UHT Sterilizer & CIP Cycles7.2 s85 min81%97.5%8,00012,000 (1.50 d)5,364
4. Aseptic Brick Filling5.7 s30 min90%97.9%4,0007,200 (0.90 d)7,791
5. Tray Wrap & Cold Store4.2 s12 min96%99.4%3,2008,800 (1.10 d)11,860

Key figures

Takt time
6.8 s
Lead time
7.20 d
Value-added time
27.0 s
Process cycle efficiency (PCE)
0.007%
Rolled throughput yield (RTY)
92.5%
Customer demand per day
8,000 packs
Line capacity per day
5,364 packs
Bottleneck
UHT Sterilizer & CIP Cycles

Reading the bottleneck

The bottleneck is "UHT Sterilizer & CIP Cycles": it can process 5,364 packs per day against a demand of 8,000 packs, so it falls short of demand by 33.0%. Once downtime and scrap are counted, its cycle time grows from 7.2 s to 9.1 s, against a takt of 6.8 s. The largest loss at this step is equipment downtime (uptime 81%), about 1.7 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.