Coconut-Starch Plant-Based Sliced Cheese Line

Product family: 200g Resealable Block Slices.

Flow: Refined Coconut Oil & Starch → Twin-Screw Steam Melt Emulsify → Chilled Block Mold 24h Set → High-Speed Orbital Log Slicer → MAP Gas-Flush Reclose Tray → X-Ray & +4°C Palletize → Supermarkets & Burger Chains

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Coconut-Starch Plant-Based Sliced Cheese LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Refined Coconut Oil & Starch → Twin-Screw Steam Melt Emulsify (2.7 s) → Chilled Block Mold 24h Set (3.3 s) → High-Speed Orbital Log Slicer (4.4 s) → MAP Gas-Flush Reclose Tray (3.5 s) → X-Ray & +4°C Palletize (2.6 s) → Supermarkets & Burger Chains.SUPPLIERRefined CoconutOil & StarchI1.20 d1Twin-Screw SteamMelt EmulsifyC/T 2.7 sI1.10 d2Chilled BlockMold 24h SetC/T 3.3 sI1.50 d3High-SpeedOrbital Log…C/T 4.4 sI0.90 d4MAP Gas-FlushReclose TrayC/T 3.5 sI1.10 d5X-Ray & +4°CPalletizeC/T 2.6 sI1.40 dCUSTOMERSupermarkets &Burger Chains13,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Twin-Screw Steam Melt Emulsify2.7 s25 min95%99.1%13,00015,600 (1.20 d)18,306
2. Chilled Block Mold 24h Set3.3 s35 min92%98.4%10,40014,300 (1.10 d)14,094
3. High-Speed Orbital Log Slicer4.4 s85 min81%97.5%13,00019,500 (1.50 d)8,777
4. MAP Gas-Flush Reclose Tray3.5 s30 min90%97.9%6,50011,700 (0.90 d)12,688
5. X-Ray & +4°C Palletize2.6 s12 min96%99.4%5,20014,300 (1.10 d)19,158

Key figures

Takt time
4.2 s
Lead time
7.20 d
Value-added time
16.5 s
Process cycle efficiency (PCE)
0.004%
Rolled throughput yield (RTY)
92.5%
Customer demand per day
13,000 packs
Line capacity per day
8,777 packs
Bottleneck
High-Speed Orbital Log Slicer

Reading the bottleneck

The bottleneck is "High-Speed Orbital Log Slicer": it can process 8,777 packs per day against a demand of 13,000 packs, so it falls short of demand by 32.5%. Once downtime and scrap are counted, its cycle time grows from 4.4 s to 5.6 s, against a takt of 4.2 s. The largest loss at this step is equipment downtime (uptime 81%), about 1.0 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Dairy, UHT & Plant-Based Alt: Dairy, UHT & Plant-Based Alt