Fresh Triple-Wash Chilled Deli Pasta Salad

Product family: 300g Tamper-Evident Bowls.

Flow: Blanched Pasta & Fresh Veg → Ozone Ice-Water Veg Wash → Chilled Blend & Volumetric Fill → Foil Heat-Seal Film Membrane → Snap Clear Lid & Weight Check → +2°C Crate & Same-Night Drop → ConvenienceGrab & Go

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Fresh Triple-Wash Chilled Deli Pasta SaladSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Blanched Pasta & Fresh Veg → Ozone Ice-Water Veg Wash (2.5 s) → Chilled Blend & Volumetric Fill (3.0 s) → Foil Heat-Seal Film Membrane (3.9 s) → Snap Clear Lid & Weight Check (2.5 s) → +2°C Crate & Same-Night Drop (2.0 s) → ConvenienceGrab & Go.SUPPLIERBlanched Pasta& Fresh VegI0.60 d1Ozone Ice-WaterVeg WashC/T 2.5 sI0.70 d2Chilled Blend &Volumetric FillC/T 3.0 sI0.90 d3Foil Heat-SealFilm MembraneC/T 3.9 sI0.40 d4Snap Clear Lid &Weight CheckC/T 2.5 sI0.40 d5+2°C Crate &Same-Night DropC/T 2.0 sI0.50 dCUSTOMERConvenienceGrab& Go15,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Ozone Ice-Water Veg Wash2.5 s15 min95%97.6%4,5009,000 (0.60 d)18,915
2. Chilled Blend & Volumetric Fill3.0 s20 min92%98.2%6,00010,500 (0.70 d)15,358
3. Foil Heat-Seal Film Membrane3.9 s30 min84%96.4%7,50013,500 (0.90 d)10,465
4. Snap Clear Lid & Weight Check2.5 s10 min95%98.8%3,0006,000 (0.40 d)19,147
5. +2°C Crate & Same-Night Drop2.0 s8 min97%99.4%3,0006,000 (0.40 d)24,876

Key figures

Takt time
3.6 s
Lead time
3.50 d
Value-added time
13.9 s
Process cycle efficiency (PCE)
0.007%
Rolled throughput yield (RTY)
90.7%
Customer demand per day
15,000 packs
Line capacity per day
10,465 packs
Bottleneck
Foil Heat-Seal Film Membrane

Reading the bottleneck

The bottleneck is "Foil Heat-Seal Film Membrane": it can process 10,465 packs per day against a demand of 15,000 packs, so it falls short of demand by 30.2%. Once downtime and scrap are counted, its cycle time grows from 3.9 s to 4.8 s, against a takt of 3.6 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.7 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Meat, Poultry & Seafood Processing: Meat, Poultry & Seafood Processing