Folded Gyoza & Dumpling Steaming IQF Line

Product family: 500g Authentic Asian Dumplings.

Flow: Wheat Sheet & Pork/Veg Mix → Continuous Dough Sheet Thin → High-Speed Encrust & Pleat → Direct Steam Gel Tunnel → Blast Spiral Freeze -35°C → Multi-Head Weigh Pillow Bag → Retail & Ethnic Supermarkets

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Folded Gyoza & Dumpling Steaming IQF LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Wheat Sheet & Pork/Veg Mix → Continuous Dough Sheet Thin (2.0 s) → High-Speed Encrust & Pleat (2.5 s) → Direct Steam Gel Tunnel (3.2 s) → Blast Spiral Freeze -35°C (2.2 s) → Multi-Head Weigh Pillow Bag (1.7 s) → Retail & Ethnic Supermarkets.SUPPLIERWheat Sheet &Pork/Veg MixI1.10 d1Continuous DoughSheet ThinC/T 2.0 sI1.30 d2High-SpeedEncrust & PleatC/T 2.5 sI1.80 d3Direct Steam GelTunnelC/T 3.2 sI0.80 d4Blast SpiralFreeze -35°CC/T 2.2 sI1.20 d5Multi-Head WeighPillow BagC/T 1.7 sI1.80 dCUSTOMERRetail & EthnicSupermarkets18,000 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Continuous Dough Sheet Thin2.0 s25 min95%98.8%14,40019,800 (1.10 d)24,462
2. High-Speed Encrust & Pleat2.5 s40 min90%97.5%14,40023,400 (1.30 d)17,901
3. Direct Steam Gel Tunnel3.2 s55 min84%96.2%18,00032,400 (1.80 d)12,803
4. Blast Spiral Freeze -35°C2.2 s8 min96%98.9%5,40014,400 (0.80 d)22,614
5. Multi-Head Weigh Pillow Bag1.7 s10 min97%99.4%5,40021,600 (1.20 d)29,493

Key figures

Takt time
3.0 s
Lead time
8.00 d
Value-added time
11.6 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
91.1%
Customer demand per day
18,000 packs
Line capacity per day
12,803 packs
Bottleneck
Direct Steam Gel Tunnel

Reading the bottleneck

The bottleneck is "Direct Steam Gel Tunnel": it can process 12,803 packs per day against a demand of 18,000 packs, so it falls short of demand by 28.9%. Once downtime and scrap are counted, its cycle time grows from 3.2 s to 4.0 s, against a takt of 3.0 s. The largest loss at this step is equipment downtime (uptime 84%), about 0.6 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Frozen Meals, Retort & Pet Food: Frozen Meals, Retort & Pet Food