3T Outpatient MRI Diagnostic Imaging Flow

Product family: 30-Min Zero-Idle Magnet Slots.

Flow: Contrast & Coil Clean Kits → Safety Metal Screen Pre-Call → Contrast IV Prep in Sub-Wait → Dual-Table Dock 3T Magnet Scan → PACS Tech Recon & Coil Wipe → Teleradiology Report <4h → Referring Specialists & PACS

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 3T Outpatient MRI Diagnostic Imaging FlowSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Contrast & Coil Clean Kits → Safety Metal Screen Pre-Call (771 s) → Contrast IV Prep in Sub-Wait (1,003 s) → Dual-Table Dock 3T Magnet Scan (1,363 s) → PACS Tech Recon & Coil Wipe (977 s) → Teleradiology Report <4h (617 s) → Referring Specialists & PACS.SUPPLIERContrast & CoilClean KitsI0.69 d1Safety MetalScreen Pre-CallC/T 771 sI1.00 d2Contrast IV Prepin Sub-WaitC/T 1,003 sI1.40 d3Dual-Table Dock3T Magnet ScanC/T 1,363 sI0.60 d4PACS Tech Recon &Coil WipeC/T 977 sI0.31 d5TeleradiologyReport <4hC/T 617 sI0.40 dCUSTOMERReferringSpecialists &…42 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Safety Metal Screen Pre-Call771 s5 min97%98.2%1329 (0.69 d)66
2. Contrast IV Prep in Sub-Wait1,003 s10 min93%98.5%1342 (1.00 d)48
3. Dual-Table Dock 3T Magnet Scan1,363 s20 min84%94.0%1759 (1.40 d)30
4. PACS Tech Recon & Coil Wipe977 s3 min96%98.8%825 (0.60 d)52
5. Teleradiology Report <4h617 s2 min99%99.6%413 (0.31 d)84

Key figures

Takt time
1,286 s
Lead time
4.49 d
Value-added time
4,731 s
Process cycle efficiency (PCE)
2.0%
Rolled throughput yield (RTY)
89.5%
Customer demand per day
42 patients
Line capacity per day
30 patients
Bottleneck
Dual-Table Dock 3T Magnet Scan

Reading the bottleneck

The bottleneck is "Dual-Table Dock 3T Magnet Scan": it can process 30 patients per day against a demand of 42 patients, so it falls short of demand by 29.6%. Once downtime and scrap are counted, its cycle time grows from 1,363 s to 1,726 s, against a takt of 1,286 s. The largest loss at this step is equipment downtime (uptime 84%), about 260 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.