Hospital Blood Transfusion Cross-Match Issue

Product family: Type-Screen & RBC Release.

Flow: Blood Component Stock → Dual-Verify Tube & ABO Gel → Antibody Screen Column Test → Electronic / Serology Cross → Blood Fridge Barcode Issue → Pneumatic Tube STAT OR Drop → Operating Rooms & Trauma

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Hospital Blood Transfusion Cross-Match IssueSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Blood Component Stock → Dual-Verify Tube & ABO Gel (270 s) → Antibody Screen Column Test (351 s) → Electronic / Serology Cross (477 s) → Blood Fridge Barcode Issue (342 s) → Pneumatic Tube STAT OR Drop (216 s) → Operating Rooms & Trauma.SUPPLIERBlood ComponentStockI0.70 d1Dual-Verify Tube& ABO GelC/T 270 sI1.00 d2Antibody ScreenColumn TestC/T 351 sI1.40 d3Electronic /Serology CrossC/T 477 sI0.60 d4Blood FridgeBarcode IssueC/T 342 sI0.30 d5Pneumatic TubeSTAT OR DropC/T 216 sI0.40 dCUSTOMEROperating Rooms& Trauma180 / samples

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Dual-Verify Tube & ABO Gel270 s5 min97%98.2%54126 (0.70 d)282
2. Antibody Screen Column Test351 s10 min93%98.5%54180 (1.00 d)206
3. Electronic / Serology Cross477 s20 min84%94.0%72252 (1.40 d)129
4. Blood Fridge Barcode Issue342 s3 min96%98.8%36108 (0.60 d)222
5. Pneumatic Tube STAT OR Drop216 s2 min99%99.6%1854 (0.30 d)364

Key figures

Takt time
450 s
Lead time
4.42 d
Value-added time
1,656 s
Process cycle efficiency (PCE)
0.46%
Rolled throughput yield (RTY)
89.5%
Customer demand per day
180 samples
Line capacity per day
129 samples
Bottleneck
Electronic / Serology Cross

Reading the bottleneck

The bottleneck is "Electronic / Serology Cross": it can process 129 samples per day against a demand of 180 samples, so it falls short of demand by 28.3%. Once downtime and scrap are counted, its cycle time grows from 477 s to 604 s, against a takt of 450 s. The largest loss at this step is equipment downtime (uptime 84%), about 90.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.