In-Clinic & Home Polysomnography Sleep Study

Product family: OSA CPAP Titration Lab.

Flow: Sleep Monitoring Headboxes → Evening Hook-Up or Home Kit → Overnight Sleep Signal Capture → AI Stage Auto-Scoring Review → Sleep Physician Apnea Index → Mask Fit & Cloud CPAP Setup → Sleep Medicine Clinics

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: In-Clinic & Home Polysomnography Sleep StudySupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Sleep Monitoring Headboxes → Evening Hook-Up or Home Kit (506 s) → Overnight Sleep Signal Capture (658 s) → AI Stage Auto-Scoring Review (894 s) → Sleep Physician Apnea Index (641 s) → Mask Fit & Cloud CPAP Setup (405 s) → Sleep Medicine Clinics.SUPPLIERSleepMonitoringHeadboxesI0.69 d1Evening Hook-Upor Home KitC/T 506 sI1.00 d2Overnight SleepSignal CaptureC/T 658 sI1.41 d3AI StageAuto-Scoring…C/T 894 sI0.59 d4Sleep PhysicianApnea IndexC/T 641 sI0.31 d5Mask Fit & CloudCPAP SetupC/T 405 sI0.41 dCUSTOMERSleep MedicineClinics32 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Evening Hook-Up or Home Kit506 s5 min97%98.2%1022 (0.69 d)49
2. Overnight Sleep Signal Capture658 s10 min93%98.5%1032 (1.00 d)35
3. AI Stage Auto-Scoring Review894 s20 min84%94.0%1345 (1.41 d)21
4. Sleep Physician Apnea Index641 s3 min96%98.8%619 (0.59 d)39
5. Mask Fit & Cloud CPAP Setup405 s2 min99%99.6%310 (0.31 d)63

Key figures

Takt time
844 s
Lead time
4.52 d
Value-added time
3,104 s
Process cycle efficiency (PCE)
2.5%
Rolled throughput yield (RTY)
89.5%
Customer demand per day
32 patients
Line capacity per day
21 patients
Bottleneck
AI Stage Auto-Scoring Review

Reading the bottleneck

The bottleneck is "AI Stage Auto-Scoring Review": it can process 21 patients per day against a demand of 32 patients, so it falls short of demand by 33.6%. Once downtime and scrap are counted, its cycle time grows from 894 s to 1,132 s, against a takt of 844 s. The largest loss at this step is equipment downtime (uptime 84%), about 170 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Clinical Labs, Imaging & Pathology: Clinical Labs, Imaging & Pathology