Cancer Tissue Biopsy Histopathology & Stain Lab

Product family: Formalin-to-Slide Pathologist.

Flow: OR Surgical Biopsy Cassettes → Grossing Dissection & Cassette → Overnight Tissue Processor → Microtome 4um Wax Ribbon Cut → H&E / IHC Auto-Stain & Scan → Digital Whole-Slide Diagnosis → Oncology Tumor Boards

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Cancer Tissue Biopsy Histopathology & Stain LabSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. OR Surgical Biopsy Cassettes → Grossing Dissection & Cassette (38.6 s) → Overnight Tissue Processor (50.0 s) → Microtome 4um Wax Ribbon Cut (68.0 s) → H&E / IHC Auto-Stain & Scan (49.0 s) → Digital Whole-Slide Diagnosis (30.9 s) → Oncology Tumor Boards.SUPPLIEROR SurgicalBiopsyCassettesI0.70 d1GrossingDissection &…C/T 38.6 sI1.00 d2Overnight TissueProcessorC/T 50.0 sI1.40 d3Microtome 4um WaxRibbon CutC/T 68.0 sI0.60 d4H&E / IHCAuto-Stain & ScanC/T 49.0 sI0.30 d5DigitalWhole-Slide…C/T 30.9 sI0.40 dCUSTOMEROncology TumorBoards420 / samples

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Grossing Dissection & Cassette38.6 s5 min97%98.2%126294 (0.70 d)642
2. Overnight Tissue Processor50.0 s10 min93%98.5%126420 (1.00 d)458
3. Microtome 4um Wax Ribbon Cut68.0 s20 min84%94.0%168588 (1.40 d)279
4. H&E / IHC Auto-Stain & Scan49.0 s3 min96%98.8%84252 (0.60 d)505
5. Digital Whole-Slide Diagnosis30.9 s2 min99%99.6%42126 (0.30 d)823

Key figures

Takt time
64.3 s
Lead time
4.41 d
Value-added time
237 s
Process cycle efficiency (PCE)
0.20%
Rolled throughput yield (RTY)
89.5%
Customer demand per day
420 samples
Line capacity per day
279 samples
Bottleneck
Microtome 4um Wax Ribbon Cut

Reading the bottleneck

The bottleneck is "Microtome 4um Wax Ribbon Cut": it can process 279 samples per day against a demand of 420 samples, so it falls short of demand by 33.6%. Once downtime and scrap are counted, its cycle time grows from 68.0 s to 86.1 s, against a takt of 64.3 s. The largest loss at this step is equipment downtime (uptime 84%), about 13.0 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Clinical Labs, Imaging & Pathology: Clinical Labs, Imaging & Pathology