All-Laser Femtosecond LASIK Eye Correction

Product family: 15-Min Bilateral Refractive Loop.

Flow: Femtosecond Laser Sterile Cones → Corneal Topography Map Check → Numbing Drop & Relax Lounge → Femto Flap & Excimer Ablate → Dark Slit-Lamp Flap Verify → Protective Shields & Next-Day → Refractive Surgery Patients

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: All-Laser Femtosecond LASIK Eye CorrectionSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Femtosecond Laser Sterile Cones → Corneal Topography Map Check (489 s) → Numbing Drop & Relax Lounge (675 s) → Femto Flap & Excimer Ablate (903 s) → Dark Slit-Lamp Flap Verify (624 s) → Protective Shields & Next-Day (422 s) → Refractive Surgery Patients.SUPPLIERFemtosecondLaser SterileConesI0.59 d1CornealTopography Map…C/T 489 sI0.69 d2Numbing Drop &Relax LoungeC/T 675 sI1.09 d3Femto Flap &Excimer AblateC/T 903 sI0.50 d4Dark Slit-LampFlap VerifyC/T 624 sI0.31 d5ProtectiveShields &…C/T 422 sI0.19 dCUSTOMERRefractiveSurgery…32 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Corneal Topography Map Check489 s4 min97%96.5%619 (0.59 d)49
2. Numbing Drop & Relax Lounge675 s6 min94%97.6%522 (0.69 d)34
3. Femto Flap & Excimer Ablate903 s10 min86%94.5%535 (1.09 d)21
4. Dark Slit-Lamp Flap Verify624 s5 min95%98.4%316 (0.50 d)36
5. Protective Shields & Next-Day422 s3 min98%99.2%310 (0.31 d)58

Key figures

Takt time
844 s
Lead time
3.49 d
Value-added time
3,113 s
Process cycle efficiency (PCE)
3.3%
Rolled throughput yield (RTY)
86.9%
Customer demand per day
32 patients
Line capacity per day
21 patients
Bottleneck
Femto Flap & Excimer Ablate

Reading the bottleneck

The bottleneck is "Femto Flap & Excimer Ablate": it can process 21 patients per day against a demand of 32 patients, so it falls short of demand by 34.9%. Once downtime and scrap are counted, its cycle time grows from 903 s to 1,111 s, against a takt of 844 s. The largest loss at this step is equipment downtime (uptime 86%), about 147 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Rehab, Screening & Outpatient Clinics: Rehab, Screening & Outpatient Clinics