Post-Hospital Skilled Nursing Home Transition

Product family: Zero-Error Med Transfer.

Flow: Hospital Discharge Summaries → Bed Hold & Insurance Pre-Auth → Ambulance Stretcher Admission → Pharmacist 100% Med Reconcil → Fall-Risk & Swallow Assessment → 72-Hr Care Plan Family Call → Skilled Rehab Units

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Post-Hospital Skilled Nursing Home TransitionSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Hospital Discharge Summaries → Bed Hold & Insurance Pre-Auth (870 s) → Ambulance Stretcher Admission (1,200 s) → Pharmacist 100% Med Reconcil (1,605 s) → Fall-Risk & Swallow Assessment (1,110 s) → 72-Hr Care Plan Family Call (750 s) → Skilled Rehab Units.SUPPLIERHospitalDischargeSummariesI0.61 d1Bed Hold &Insurance…C/T 870 sI0.72 d2AmbulanceStretcher…C/T 1,200 sI1.11 d3Pharmacist 100%Med ReconcilC/T 1,605 sI0.50 d4Fall-Risk &Swallow…C/T 1,110 sI0.28 d572-Hr Care PlanFamily CallC/T 750 sI0.22 dCUSTOMERSkilled RehabUnits18 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Bed Hold & Insurance Pre-Auth870 s4 min97%96.5%411 (0.61 d)28
2. Ambulance Stretcher Admission1,200 s6 min94%97.6%313 (0.72 d)19
3. Pharmacist 100% Med Reconcil1,605 s10 min86%94.5%320 (1.11 d)12
4. Fall-Risk & Swallow Assessment1,110 s5 min95%98.4%29 (0.50 d)20
5. 72-Hr Care Plan Family Call750 s3 min98%99.2%25 (0.28 d)33

Key figures

Takt time
1,500 s
Lead time
3.65 d
Value-added time
5,535 s
Process cycle efficiency (PCE)
5.6%
Rolled throughput yield (RTY)
86.9%
Customer demand per day
18 patients
Line capacity per day
12 patients
Bottleneck
Pharmacist 100% Med Reconcil

Reading the bottleneck

The bottleneck is "Pharmacist 100% Med Reconcil": it can process 12 patients per day against a demand of 18 patients, so it falls short of demand by 34.2%. Once downtime and scrap are counted, its cycle time grows from 1,605 s to 1,975 s, against a takt of 1,500 s. The largest loss at this step is equipment downtime (uptime 86%), about 261 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Rehab, Screening & Outpatient Clinics: Rehab, Screening & Outpatient Clinics