Executive 3-Hour Whole-Body Preventive Checkup

Product family: Zero-Wait Coordinated Circuit.

Flow: Lab Draw & Ultrasound Gels → Fasting Lab Blood & Urine Draw → Light Breakfast & DEXA Scan → Cardio Stress Test & Echo → Skin Mole & Vision Screen → Same-Day MD Synthesis Plan → Corporate & Self-Pay Clients

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Executive 3-Hour Whole-Body Preventive CheckupSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Lab Draw & Ultrasound Gels → Fasting Lab Blood & Urine Draw (653 s) → Light Breakfast & DEXA Scan (900 s) → Cardio Stress Test & Echo (1,204 s) → Skin Mole & Vision Screen (833 s) → Same-Day MD Synthesis Plan (563 s) → Corporate & Self-Pay Clients.SUPPLIERLab Draw &Ultrasound GelsI0.58 d1Fasting Lab Blood& Urine DrawC/T 653 sI0.71 d2Light Breakfast &DEXA ScanC/T 900 sI1.08 d3Cardio StressTest & EchoC/T 1,204 sI0.50 d4Skin Mole &Vision ScreenC/T 833 sI0.29 d5Same-Day MDSynthesis PlanC/T 563 sI0.21 dCUSTOMERCorporate &Self-Pay…24 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Fasting Lab Blood & Urine Draw653 s4 min97%96.5%514 (0.58 d)37
2. Light Breakfast & DEXA Scan900 s6 min94%97.6%417 (0.71 d)25
3. Cardio Stress Test & Echo1,204 s10 min86%94.5%426 (1.08 d)16
4. Skin Mole & Vision Screen833 s5 min95%98.4%212 (0.50 d)26
5. Same-Day MD Synthesis Plan563 s3 min98%99.2%27 (0.29 d)43

Key figures

Takt time
1,125 s
Lead time
3.53 d
Value-added time
4,153 s
Process cycle efficiency (PCE)
4.4%
Rolled throughput yield (RTY)
86.9%
Customer demand per day
24 patients
Line capacity per day
16 patients
Bottleneck
Cardio Stress Test & Echo

Reading the bottleneck

The bottleneck is "Cardio Stress Test & Echo": it can process 16 patients per day against a demand of 24 patients, so it falls short of demand by 34.2%. Once downtime and scrap are counted, its cycle time grows from 1,204 s to 1,481 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 86%), about 196 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Rehab, Screening & Outpatient Clinics: Rehab, Screening & Outpatient Clinics