Musculoskeletal Sports Physio & ACL Return Clinic

Product family: 45-Min Therapy Flow.

Flow: Rehab Bands & Shockwave Tips → Tablet Pain & ROM Check-In → Force-Plate Gait Biofeedback → Hands-On Manual & Dry-Needle → Supervised Eccentric Gym Pod → App Home Video Program Push → Orthopedic Post-Op Athletes

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Musculoskeletal Sports Physio & ACL Return ClinicSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Rehab Bands & Shockwave Tips → Tablet Pain & ROM Check-In (184 s) → Force-Plate Gait Biofeedback (254 s) → Hands-On Manual & Dry-Needle (340 s) → Supervised Eccentric Gym Pod (235 s) → App Home Video Program Push (159 s) → Orthopedic Post-Op Athletes.SUPPLIERRehab Bands &Shockwave TipsI0.60 d1Tablet Pain & ROMCheck-InC/T 184 sI0.69 d2Force-Plate GaitBiofeedbackC/T 254 sI1.11 d3Hands-On Manual &Dry-NeedleC/T 340 sI0.51 d4SupervisedEccentric Gym PodC/T 235 sI0.31 d5App Home VideoProgram PushC/T 159 sI0.20 dCUSTOMEROrthopedicPost-Op…85 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Tablet Pain & ROM Check-In184 s4 min97%96.5%1751 (0.60 d)131
2. Force-Plate Gait Biofeedback254 s6 min94%97.6%1359 (0.69 d)89
3. Hands-On Manual & Dry-Needle340 s10 min86%94.5%1394 (1.11 d)55
4. Supervised Eccentric Gym Pod235 s5 min95%98.4%943 (0.51 d)96
5. App Home Video Program Push159 s3 min98%99.2%926 (0.31 d)155

Key figures

Takt time
318 s
Lead time
3.46 d
Value-added time
1,172 s
Process cycle efficiency (PCE)
1.3%
Rolled throughput yield (RTY)
86.9%
Customer demand per day
85 patients
Line capacity per day
55 patients
Bottleneck
Hands-On Manual & Dry-Needle

Reading the bottleneck

The bottleneck is "Hands-On Manual & Dry-Needle": it can process 55 patients per day against a demand of 85 patients, so it falls short of demand by 35.1%. Once downtime and scrap are counted, its cycle time grows from 340 s to 418 s, against a takt of 318 s. The largest loss at this step is equipment downtime (uptime 86%), about 55.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Rehab, Screening & Outpatient Clinics: Rehab, Screening & Outpatient Clinics