Supervised Telemetry Phase-II Cardiac Rehab Pod

Product family: Monitored Group Bike/Treadmill.

Flow: Wireless 3-Lead ECG Telemetry → Pre-Exercise BP & Weight Log → Wireless Telemetry Vest Fit → 40-Min Monitored Interval Gym → Cool-Down & Lactate Check → Weekly Cardiologist Progress → Post-MI & Bypass Patients

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Supervised Telemetry Phase-II Cardiac Rehab PodSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Wireless 3-Lead ECG Telemetry → Pre-Exercise BP & Weight Log (326 s) → Wireless Telemetry Vest Fit (450 s) → 40-Min Monitored Interval Gym (602 s) → Cool-Down & Lactate Check (416 s) → Weekly Cardiologist Progress (281 s) → Post-MI & Bypass Patients.SUPPLIERWireless 3-LeadECG TelemetryI0.60 d1Pre-Exercise BP &Weight LogC/T 326 sI0.71 d2WirelessTelemetry Vest…C/T 450 sI1.10 d340-Min MonitoredInterval GymC/T 602 sI0.50 d4Cool-Down &Lactate CheckC/T 416 sI0.29 d5WeeklyCardiologist…C/T 281 sI0.21 dCUSTOMERPost-MI &Bypass Patients48 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Pre-Exercise BP & Weight Log326 s4 min97%96.5%1029 (0.60 d)74
2. Wireless Telemetry Vest Fit450 s6 min94%97.6%734 (0.71 d)50
3. 40-Min Monitored Interval Gym602 s10 min86%94.5%753 (1.10 d)31
4. Cool-Down & Lactate Check416 s5 min95%98.4%524 (0.50 d)54
5. Weekly Cardiologist Progress281 s3 min98%99.2%514 (0.29 d)87

Key figures

Takt time
563 s
Lead time
3.49 d
Value-added time
2,075 s
Process cycle efficiency (PCE)
2.2%
Rolled throughput yield (RTY)
86.9%
Customer demand per day
48 patients
Line capacity per day
31 patients
Bottleneck
40-Min Monitored Interval Gym

Reading the bottleneck

The bottleneck is "40-Min Monitored Interval Gym": it can process 31 patients per day against a demand of 48 patients, so it falls short of demand by 35.6%. Once downtime and scrap are counted, its cycle time grows from 602 s to 741 s, against a takt of 563 s. The largest loss at this step is equipment downtime (uptime 86%), about 98.0 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Rehab, Screening & Outpatient Clinics: Rehab, Screening & Outpatient Clinics