Sub-Millimeter Titanium Orthopedic Bone Screw

Product family: Swiss-Turned Dental & Spine Screws.

Flow: Medical titanium supplier → Multi-Channel Swiss Turn → Star-Drive Broach → Ultrasonic Degrease & Passiv → Anodize Color Size Code → Vision Thread & Burrs 100% → MedTech Orthopedic Plants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Sub-Millimeter Titanium Orthopedic Bone ScrewSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Medical titanium supplier → Multi-Channel Swiss Turn (11.2 s) → Star-Drive Broach (13.1 s) → Ultrasonic Degrease & Passiv (16.7 s) → Anodize Color Size Code (11.8 s) → Vision Thread & Burrs 100% (8.7 s) → MedTech Orthopedic Plants.SUPPLIERMedicaltitaniumsupplierI2.20 d1Multi-ChannelSwiss TurnC/T 11.2 sI1.80 d2Star-Drive BroachC/T 13.1 sI2.40 d3UltrasonicDegrease & PassivC/T 16.7 sI1.50 d4Anodize ColorSize CodeC/T 11.8 sI0.80 d5Vision Thread &Burrs 100%C/T 8.7 sI2.00 dCUSTOMERMedTechOrthopedic…5,200 / parts

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Multi-Channel Swiss Turn11.2 s65 min90%98.8%10,40011,440 (2.20 d)6,276
2. Star-Drive Broach13.1 s45 min91%97.6%7,8009,360 (1.80 d)5,370
3. Ultrasonic Degrease & Passiv16.7 s50 min84%96.1%7,80012,480 (2.40 d)3,819
4. Anodize Color Size Code11.8 s20 min93%98.4%5,2007,800 (1.50 d)6,189
5. Vision Thread & Burrs 100%8.7 s12 min97%99.6%2,6004,160 (0.80 d)8,835

Key figures

Takt time
15.6 s
Lead time
10.7 d
Value-added time
61.5 s
Process cycle efficiency (PCE)
0.007%
Rolled throughput yield (RTY)
90.8%
Customer demand per day
5,200 parts
Line capacity per day
3,819 parts
Bottleneck
Ultrasonic Degrease & Passiv

Reading the bottleneck

The bottleneck is "Ultrasonic Degrease & Passiv": it can process 3,819 parts per day against a demand of 5,200 parts, so it falls short of demand by 26.6%. Once downtime and scrap are counted, its cycle time grows from 16.7 s to 20.7 s, against a takt of 15.6 s. The largest loss at this step is equipment downtime (uptime 84%), about 3.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Bearings, Gears & Precision Fasteners: Bearings, Gears & Precision Fasteners