Induction-Hardened 4-Cyl Forged Crankshaft

Product family: Micro-Alloy Diesel Crankshafts.

Flow: Crankshaft forge → Milling Mass-Center Datum → Turn-Broach Main Journals → Pin & Main Induction Harden → CBN Orbital Crankpin Grind → Superfinish Belt & Mag-Check → Commercial Diesel Engines

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Induction-Hardened 4-Cyl Forged CrankshaftSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Crankshaft forge → Milling Mass-Center Datum (81.0 s) → Turn-Broach Main Journals (95.0 s) → Pin & Main Induction Harden (120 s) → CBN Orbital Crankpin Grind (86.0 s) → Superfinish Belt & Mag-Check (63.0 s) → Commercial Diesel Engines.SUPPLIERCrankshaftforgeI2.20 d1MillingMass-Center DatumC/T 81.0 sI1.80 d2Turn-Broach MainJournalsC/T 95.0 sI2.40 d3Pin & MainInduction HardenC/T 120 sI1.50 d4CBN OrbitalCrankpin GrindC/T 86.0 sI0.80 d5Superfinish Belt& Mag-CheckC/T 63.0 sI2.00 dCUSTOMERCommercialDiesel Engines480 / parts

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Milling Mass-Center Datum81.0 s65 min90%98.8%9601,056 (2.20 d)571
2. Turn-Broach Main Journals95.0 s45 min91%97.6%720864 (1.80 d)488
3. Pin & Main Induction Harden120 s50 min84%96.1%7201,152 (2.40 d)350
4. CBN Orbital Crankpin Grind86.0 s20 min93%98.4%480720 (1.50 d)562
5. Superfinish Belt & Mag-Check63.0 s12 min97%99.6%240384 (0.80 d)806

Key figures

Takt time
113 s
Lead time
10.7 d
Value-added time
445 s
Process cycle efficiency (PCE)
0.077%
Rolled throughput yield (RTY)
90.8%
Customer demand per day
480 parts
Line capacity per day
350 parts
Bottleneck
Pin & Main Induction Harden

Reading the bottleneck

The bottleneck is "Pin & Main Induction Harden": it can process 350 parts per day against a demand of 480 parts, so it falls short of demand by 27.1%. Once downtime and scrap are counted, its cycle time grows from 120 s to 149 s, against a takt of 113 s. The largest loss at this step is equipment downtime (uptime 84%), about 22.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Bearings, Gears & Precision Fasteners: Bearings, Gears & Precision Fasteners