800kW Magnetic-Bearing Centrifugal Chiller

Product family: R1234ze Oil-Free HVAC Chillers.

Flow: Magnetic-bearing compressor supplier → Copper-Tube Shell Evap Roll → Orbital Pipe & Brazing Deck → Turbo Compressor Manifold Fit → VFD Cabinet & Nitrogen Hold → AHRI Part-Load Calorimeter → Data Center Cooling Plants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 800kW Magnetic-Bearing Centrifugal ChillerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Magnetic-bearing compressor supplier → Copper-Tube Shell Evap Roll (3,060 s) → Orbital Pipe & Brazing Deck (3,870 s) → Turbo Compressor Manifold Fit (4,860 s) → VFD Cabinet & Nitrogen Hold (3,510 s) → AHRI Part-Load Calorimeter (2,700 s) → Data Center Cooling Plants.SUPPLIERMagnetic-bearingcompressorsupplierI1.67 d1Copper-Tube ShellEvap RollC/T 3,060 sI1.83 d2Orbital Pipe &Brazing DeckC/T 3,870 sI2.17 d3Turbo CompressorManifold FitC/T 4,860 sI1.17 d4VFD Cabinet &Nitrogen HoldC/T 3,510 sI0.83 d5AHRI Part-LoadCalorimeterC/T 2,700 sI1.50 dCUSTOMERData CenterCooling Plants6 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Copper-Tube Shell Evap Roll3,060 s35 min93%98.7%910 (1.67 d)8
2. Orbital Pipe & Brazing Deck3,870 s30 min90%96.9%511 (1.83 d)6
3. Turbo Compressor Manifold Fit4,860 s45 min84%95.5%613 (2.17 d)4
4. VFD Cabinet & Nitrogen Hold3,510 s15 min94%98.3%27 (1.17 d)6
5. AHRI Part-Load Calorimeter2,700 s8 min96%99.1%15 (0.83 d)9

Key figures

Takt time
4,500 s
Lead time
9.83 d
Value-added time
18,000 s
Process cycle efficiency (PCE)
6.8%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
6 units
Line capacity per day
4 units
Bottleneck
Turbo Compressor Manifold Fit

Reading the bottleneck

The bottleneck is "Turbo Compressor Manifold Fit": it can process 4 units per day against a demand of 6 units, so it falls short of demand by 33.2%. Once downtime and scrap are counted, its cycle time grows from 4,860 s to 6,058 s, against a takt of 4,500 s. The largest loss at this step is equipment downtime (uptime 84%), about 926 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Electric Motors, HVAC & Heat Transfer: Electric Motors, HVAC & Heat Transfer