Pultruded FRP Crossflow Industrial Cooling Tower

Product family: Modular Evaporative Cells.

Flow: FRP profile supplier → FRP Pultrusion Mitre & Drill → Basin Seal & Drift Eliminator → Axial FRP Fan & Gear Drive → PVC Film-Fill Block Stack → Vibration & Air-Flow Cert → Industrial & HVAC Plants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Pultruded FRP Crossflow Industrial Cooling TowerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. FRP profile supplier → FRP Pultrusion Mitre & Drill (1,311 s) → Basin Seal & Drift Eliminator (1,659 s) → Axial FRP Fan & Gear Drive (2,083 s) → PVC Film-Fill Block Stack (1,504 s) → Vibration & Air-Flow Cert (1,157 s) → Industrial & HVAC Plants.SUPPLIERFRP profilesupplierI1.71 d1FRP PultrusionMitre & DrillC/T 1,311 sI1.79 d2Basin Seal &Drift EliminatorC/T 1,659 sI2.21 d3Axial FRP Fan &Gear DriveC/T 2,083 sI1.07 d4PVC Film-FillBlock StackC/T 1,504 sI0.79 d5Vibration &Air-Flow CertC/T 1,157 sI1.50 dCUSTOMERIndustrial &HVAC Plants14 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. FRP Pultrusion Mitre & Drill1,311 s35 min93%98.7%2124 (1.71 d)18
2. Basin Seal & Drift Eliminator1,659 s30 min90%96.9%1125 (1.79 d)13
3. Axial FRP Fan & Gear Drive2,083 s45 min84%95.5%1431 (2.21 d)9
4. PVC Film-Fill Block Stack1,504 s15 min94%98.3%615 (1.07 d)15
5. Vibration & Air-Flow Cert1,157 s8 min96%99.1%311 (0.79 d)20

Key figures

Takt time
1,929 s
Lead time
9.36 d
Value-added time
7,714 s
Process cycle efficiency (PCE)
3.1%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
14 units
Line capacity per day
9 units
Bottleneck
Axial FRP Fan & Gear Drive

Reading the bottleneck

The bottleneck is "Axial FRP Fan & Gear Drive": it can process 9 units per day against a demand of 14 units, so it falls short of demand by 33.2%. Once downtime and scrap are counted, its cycle time grows from 2,083 s to 2,597 s, against a takt of 1,929 s. The largest loss at this step is equipment downtime (uptime 84%), about 397 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.