Alu-Silica Desiccant Enthalpy Rotary Wheel

Product family: 90% Heat-Recovery AHU Wheels.

Flow: Thin-Gauge Al Foil → Foil Corrugation & Molecular Coat → Laser-Guided Rotor Spiral Wind → Hub Spoke Weld & Brush Seals → Rim Drive Motor Tension Rig → Leakage & Latent Efficiency QC → Hospital & Cleanroom AHUs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Alu-Silica Desiccant Enthalpy Rotary WheelSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Thin-Gauge Al Foil → Foil Corrugation & Molecular Coat (387 s) → Laser-Guided Rotor Spiral Wind (489 s) → Hub Spoke Weld & Brush Seals (614 s) → Rim Drive Motor Tension Rig (443 s) → Leakage & Latent Efficiency QC (341 s) → Hospital & Cleanroom AHUs.SUPPLIERThin-Gauge AlFoilI1.71 d1Foil Corrugation& Molecular CoatC/T 387 sI1.80 d2Laser-GuidedRotor Spiral WindC/T 489 sI2.20 d3Hub Spoke Weld &Brush SealsC/T 614 sI1.11 d4Rim Drive MotorTension RigC/T 443 sI0.80 d5Leakage & LatentEfficiency QCC/T 341 sI1.51 dCUSTOMERHospital &Cleanroom AHUs95 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Foil Corrugation & Molecular Coat387 s35 min93%98.7%143162 (1.71 d)125
2. Laser-Guided Rotor Spiral Wind489 s30 min90%96.9%76171 (1.80 d)92
3. Hub Spoke Weld & Brush Seals614 s45 min84%95.5%95209 (2.20 d)67
4. Rim Drive Motor Tension Rig443 s15 min94%98.3%38105 (1.11 d)108
5. Leakage & Latent Efficiency QC341 s8 min96%99.1%1976 (0.80 d)144

Key figures

Takt time
568 s
Lead time
9.16 d
Value-added time
2,274 s
Process cycle efficiency (PCE)
0.46%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
95 units
Line capacity per day
67 units
Bottleneck
Hub Spoke Weld & Brush Seals

Reading the bottleneck

The bottleneck is "Hub Spoke Weld & Brush Seals": it can process 67 units per day against a demand of 95 units, so it falls short of demand by 29.4%. Once downtime and scrap are counted, its cycle time grows from 614 s to 765 s, against a takt of 568 s. The largest loss at this step is equipment downtime (uptime 84%), about 117 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Electric Motors, HVAC & Heat Transfer: Electric Motors, HVAC & Heat Transfer