Commercial Heat-Recovery VRF Outdoor Unit

Product family: Inverter Twin-Rotary VRF Systems.

Flow: R32 Compressors & Cu Coils → Copper Fin-Coil Bending & Braze → Twin-Inverter Compressor Mount → Automated Vacuum & R32 Charge → Halogen Sniffer Leak Tunnel → 3-Mode Heat/Cool Chamber → Commercial Tower Contractors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Commercial Heat-Recovery VRF Outdoor UnitSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. R32 Compressors & Cu Coils → Copper Fin-Coil Bending & Braze (193 s) → Twin-Inverter Compressor Mount (244 s) → Automated Vacuum & R32 Charge (307 s) → Halogen Sniffer Leak Tunnel (222 s) → 3-Mode Heat/Cool Chamber (171 s) → Commercial Tower Contractors.SUPPLIERR32 Compressors& Cu CoilsI1.70 d1Copper Fin-CoilBending & BrazeC/T 193 sI1.80 d2Twin-InverterCompressor MountC/T 244 sI2.20 d3Automated Vacuum& R32 ChargeC/T 307 sI1.10 d4Halogen SnifferLeak TunnelC/T 222 sI0.80 d53-Mode Heat/CoolChamberC/T 171 sI1.50 dCUSTOMERCommercialTower…190 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Copper Fin-Coil Bending & Braze193 s35 min93%98.7%285323 (1.70 d)250
2. Twin-Inverter Compressor Mount244 s30 min90%96.9%152342 (1.80 d)185
3. Automated Vacuum & R32 Charge307 s45 min84%95.5%190418 (2.20 d)134
4. Halogen Sniffer Leak Tunnel222 s15 min94%98.3%76209 (1.10 d)215
5. 3-Mode Heat/Cool Chamber171 s8 min96%99.1%38152 (0.80 d)287

Key figures

Takt time
284 s
Lead time
9.12 d
Value-added time
1,137 s
Process cycle efficiency (PCE)
0.23%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
190 units
Line capacity per day
134 units
Bottleneck
Automated Vacuum & R32 Charge

Reading the bottleneck

The bottleneck is "Automated Vacuum & R32 Charge": it can process 134 units per day against a demand of 190 units, so it falls short of demand by 29.4%. Once downtime and scrap are counted, its cycle time grows from 307 s to 383 s, against a takt of 284 s. The largest loss at this step is equipment downtime (uptime 84%), about 58.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.