Night-Shift +2°C Fresh Dairy Cross-Docking

Product family: No-Storage Just-in-Time Dairy.

Flow: 5 Regional Dairies → High-Speed Reefer Inbound → Roller Dolly Scan-by-Store → Short Hold Buffer Allocation → Multi-Store Route Staging → Pre-Dawn Silent Store Drop → 600 Neighborhood Grocers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Night-Shift +2°C Fresh Dairy Cross-DockingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 5 Regional Dairies → High-Speed Reefer Inbound (6.1 s) → Roller Dolly Scan-by-Store (9.3 s) → Short Hold Buffer Allocation (6.6 s) → Multi-Store Route Staging (7.5 s) → Pre-Dawn Silent Store Drop (5.1 s) → 600 Neighborhood Grocers.SUPPLIER5 RegionalDairiesI0.70 d1High-Speed ReeferInboundC/T 6.1 sI1.40 d2Roller DollyScan-by-StoreC/T 9.3 sI1.20 d3Short Hold BufferAllocationC/T 6.6 sI0.80 d4Multi-Store RouteStagingC/T 7.5 sI0.50 d5Pre-Dawn SilentStore DropC/T 5.1 sI0.70 dCUSTOMER600Neighborhood…6,200 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. High-Speed Reefer Inbound6.1 s10 min96%98.8%2,4804,340 (0.70 d)8,163
2. Roller Dolly Scan-by-Store9.3 s15 min87%95.0%3,1008,680 (1.40 d)4,639
3. Short Hold Buffer Allocation6.6 s8 min94%98.4%1,8607,440 (1.20 d)7,344
4. Multi-Store Route Staging7.5 s8 min92%97.6%1,2404,960 (0.80 d)6,178
5. Pre-Dawn Silent Store Drop5.1 s10 min96%99.1%1,5503,100 (0.50 d)9,626

Key figures

Takt time
8.7 s
Lead time
5.30 d
Value-added time
34.6 s
Process cycle efficiency (PCE)
0.012%
Rolled throughput yield (RTY)
89.3%
Customer demand per day
6,200 crates
Line capacity per day
4,639 crates
Bottleneck
Roller Dolly Scan-by-Store

Reading the bottleneck

The bottleneck is "Roller Dolly Scan-by-Store": it can process 4,639 crates per day against a demand of 6,200 crates, so it falls short of demand by 25.2%. Once downtime and scrap are counted, its cycle time grows from 9.3 s to 11.3 s, against a takt of 8.7 s. The largest loss at this step is equipment downtime (uptime 87%), about 1.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cold-Chain & Temperature Logistics: Cold-Chain & Temperature Logistics