-25°C Automated Clad-Rack Deep-Freeze Hub

Product family: Full-Pallet Frozen Food Hub.

Flow: Frozen Bakery & Fries Plants → -25°C Conveyor Airlock Tunnel → 40m Stacker Crane Putaway → Robotic Layer-Picker Cell → Stretch-Wrap Freeze Film → Pre-Cooled Reefer Dock Seal → National Grocery DCs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: -25°C Automated Clad-Rack Deep-Freeze HubSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Frozen Bakery & Fries Plants → -25°C Conveyor Airlock Tunnel (25.8 s) → 40m Stacker Crane Putaway (39.4 s) → Robotic Layer-Picker Cell (28.0 s) → Stretch-Wrap Freeze Film (31.7 s) → Pre-Cooled Reefer Dock Seal (21.4 s) → National Grocery DCs.SUPPLIERFrozen Bakery &Fries PlantsI0.70 d1-25°C ConveyorAirlock TunnelC/T 25.8 sI1.40 d240m Stacker CranePutawayC/T 39.4 sI1.20 d3RoboticLayer-Picker CellC/T 28.0 sI0.80 d4Stretch-WrapFreeze FilmC/T 31.7 sI0.50 d5Pre-Cooled ReeferDock SealC/T 21.4 sI0.70 dCUSTOMERNationalGrocery DCs2,200 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. -25°C Conveyor Airlock Tunnel25.8 s10 min96%98.8%8801,540 (0.70 d)2,923
2. 40m Stacker Crane Putaway39.4 s15 min87%95.0%1,1003,080 (1.40 d)1,661
3. Robotic Layer-Picker Cell28.0 s8 min94%98.4%6602,640 (1.20 d)2,623
4. Stretch-Wrap Freeze Film31.7 s8 min92%97.6%4401,760 (0.80 d)2,226
5. Pre-Cooled Reefer Dock Seal21.4 s10 min96%99.1%5501,100 (0.50 d)3,494

Key figures

Takt time
36.8 s
Lead time
5.30 d
Value-added time
146 s
Process cycle efficiency (PCE)
0.034%
Rolled throughput yield (RTY)
89.3%
Customer demand per day
2,200 crates
Line capacity per day
1,661 crates
Bottleneck
40m Stacker Crane Putaway

Reading the bottleneck

The bottleneck is "40m Stacker Crane Putaway": it can process 1,661 crates per day against a demand of 2,200 crates, so it falls short of demand by 24.5%. Once downtime and scrap are counted, its cycle time grows from 39.4 s to 47.7 s, against a takt of 36.8 s. The largest loss at this step is equipment downtime (uptime 87%), about 5.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cold-Chain & Temperature Logistics: Cold-Chain & Temperature Logistics