Pneumatic Silo Truck Cement & Flour Tanker

Product family: Compressed-Air Blown Deliveries.

Flow: Flour Mill & Cement Silos → Allergen / Grade Wash Cert → Overhead Silo Gravity Load → Sealed Hatch Tag & Weight → Low-Pressure Pneumatic Blow → Clean Return & Moisture Check → Industrial Bakeries & Batching

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Pneumatic Silo Truck Cement & Flour TankerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Flour Mill & Cement Silos → Allergen / Grade Wash Cert (461 s) → Overhead Silo Gravity Load (590 s) → Sealed Hatch Tag & Weight (778 s) → Low-Pressure Pneumatic Blow (518 s) → Clean Return & Moisture Check (403 s) → Industrial Bakeries & Batching.SUPPLIERFlour Mill &Cement SilosI0.60 d1Allergen / GradeWash CertC/T 461 sI0.80 d2Overhead SiloGravity LoadC/T 590 sI1.00 d3Sealed Hatch Tag& WeightC/T 778 sI0.60 d4Low-PressurePneumatic BlowC/T 518 sI0.40 d5Clean Return &Moisture CheckC/T 403 sI0.40 dCUSTOMERIndustrialBakeries &…75 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Allergen / Grade Wash Cert461 s10 min96%98.4%2345 (0.60 d)107
2. Overhead Silo Gravity Load590 s12 min92%97.8%1960 (0.80 d)78
3. Sealed Hatch Tag & Weight778 s15 min85%94.5%1575 (1.00 d)51
4. Low-Pressure Pneumatic Blow518 s8 min94%97.4%1545 (0.60 d)91
5. Clean Return & Moisture Check403 s5 min98%99.1%1930 (0.40 d)127

Key figures

Takt time
720 s
Lead time
3.85 d
Value-added time
2,750 s
Process cycle efficiency (PCE)
1.3%
Rolled throughput yield (RTY)
87.8%
Customer demand per day
75 batches
Line capacity per day
51 batches
Bottleneck
Sealed Hatch Tag & Weight

Reading the bottleneck

The bottleneck is "Sealed Hatch Tag & Weight": it can process 51 batches per day against a demand of 75 batches, so it falls short of demand by 31.9%. Once downtime and scrap are counted, its cycle time grows from 778 s to 969 s, against a takt of 720 s. The largest loss at this step is equipment downtime (uptime 85%), about 137 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of 3PL Milkruns, Last-Mile & Bulk Tankers: 3PL Milkruns, Last-Mile & Bulk Tankers