Urban HORECA Cellar Drop & Empty Keg Pickup

Product family: City Bar & Pub Supply Loops.

Flow: Regional Beverage Depots → Overnight Route Pick by Cellar → Tail-Lift & Electric Stair Climb → Cellar Chiller Rotation FEFO → Empty Kegs & Glass Scan Back → Deposit Credit App Settlement → Bars, Cafes & Restaurants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Urban HORECA Cellar Drop & Empty Keg PickupSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Regional Beverage Depots → Overnight Route Pick by Cellar (25.4 s) → Tail-Lift & Electric Stair Climb (32.6 s) → Cellar Chiller Rotation FEFO (43.0 s) → Empty Kegs & Glass Scan Back (28.6 s) → Deposit Credit App Settlement (22.2 s) → Bars, Cafes & Restaurants.SUPPLIERRegionalBeverage DepotsI0.60 d1Overnight RoutePick by CellarC/T 25.4 sI0.80 d2Tail-Lift &Electric Stair…C/T 32.6 sI1.00 d3Cellar ChillerRotation FEFOC/T 43.0 sI0.60 d4Empty Kegs &Glass Scan BackC/T 28.6 sI0.40 d5Deposit CreditApp SettlementC/T 22.2 sI0.40 dCUSTOMERBars, Cafes &Restaurants680 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Overnight Route Pick by Cellar25.4 s10 min96%98.4%204408 (0.60 d)930
2. Tail-Lift & Electric Stair Climb32.6 s12 min92%97.8%170544 (0.80 d)666
3. Cellar Chiller Rotation FEFO43.0 s15 min85%94.5%136680 (1.00 d)420
4. Empty Kegs & Glass Scan Back28.6 s8 min94%97.4%136408 (0.60 d)788
5. Deposit Credit App Settlement22.2 s5 min98%99.1%170272 (0.40 d)1,129

Key figures

Takt time
39.7 s
Lead time
3.81 d
Value-added time
152 s
Process cycle efficiency (PCE)
0.15%
Rolled throughput yield (RTY)
87.8%
Customer demand per day
680 units
Line capacity per day
420 units
Bottleneck
Cellar Chiller Rotation FEFO

Reading the bottleneck

The bottleneck is "Cellar Chiller Rotation FEFO": it can process 420 units per day against a demand of 680 units, so it falls short of demand by 38.2%. Once downtime and scrap are counted, its cycle time grows from 43.0 s to 53.5 s, against a takt of 39.7 s. The largest loss at this step is equipment downtime (uptime 85%), about 7.6 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of 3PL Milkruns, Last-Mile & Bulk Tankers: 3PL Milkruns, Last-Mile & Bulk Tankers