Pre-Mixed Sterile Pain Management Mini-Bag

Product family: OR Epidural Infusion Packs.

Flow: Medical-Grade EVA Film Supplier → Bulk Analgesic Dissolution → Aseptic EVA Port Filling → Terminal Steam Air-Overpress → Secondary UV Shield Overwrap → QA Micro & Release Pack → Surgical Anesthesia Suites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Pre-Mixed Sterile Pain Management Mini-BagSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Medical-Grade EVA Film Supplier → Bulk Analgesic Dissolution (5.9 s) → Aseptic EVA Port Filling (9.4 s) → Terminal Steam Air-Overpress (6.8 s) → Secondary UV Shield Overwrap (5.6 s) → QA Micro & Release Pack (7.0 s) → Surgical Anesthesia Suites.SUPPLIERMedical-GradeEVA FilmSupplierI1.40 d1Bulk AnalgesicDissolutionC/T 5.9 sI2.20 d2Aseptic EVA PortFillingC/T 9.4 sI1.30 d3Terminal SteamAir-OverpressC/T 6.8 sI1.00 d4Secondary UVShield OverwrapC/T 5.6 sI2.40 d5QA Micro &Release PackC/T 7.0 sI1.50 dCUSTOMERSurgicalAnesthesia…6,200 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Bulk Analgesic Dissolution5.9 s45 min95%99.4%6,2008,680 (1.40 d)8,211
2. Aseptic EVA Port Filling9.4 s95 min82%95.8%6,20013,640 (2.20 d)4,036
3. Terminal Steam Air-Overpress6.8 s25 min92%96.8%3,1008,060 (1.30 d)6,679
4. Secondary UV Shield Overwrap5.6 s20 min95%99.1%2,4806,200 (1.00 d)8,574
5. QA Micro & Release Pack7.0 s10 min93%98.5%6,20014,880 (2.40 d)6,988

Key figures

Takt time
8.7 s
Lead time
9.80 d
Value-added time
34.7 s
Process cycle efficiency (PCE)
0.007%
Rolled throughput yield (RTY)
90.0%
Customer demand per day
6,200 packs
Line capacity per day
4,036 packs
Bottleneck
Aseptic EVA Port Filling

Reading the bottleneck

The bottleneck is "Aseptic EVA Port Filling": it can process 4,036 packs per day against a demand of 6,200 packs, so it falls short of demand by 34.9%. Once downtime and scrap are counted, its cycle time grows from 9.4 s to 12.0 s, against a takt of 8.7 s. The largest loss at this step is equipment downtime (uptime 82%), about 2.1 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Sterile Injectable & Aseptic GMP: Sterile Injectable & Aseptic GMP