Sterile Anticoagulant Heparin Multi-Dose Vial

Product family: ICU Critical Care Heparin.

Flow: Heparin API Supplier → 0.22um Redundant Filtration → Vial Wash-Tunnel-Fill-Stopper → Steam Terminal Sterilization → Optical Particle Camera Scan → Track & Trace Carton Bundle → Acute Hospital Pharmacies

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Sterile Anticoagulant Heparin Multi-Dose VialSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Heparin API Supplier → 0.22um Redundant Filtration (2.6 s) → Vial Wash-Tunnel-Fill-Stopper (4.2 s) → Steam Terminal Sterilization (3.0 s) → Optical Particle Camera Scan (2.5 s) → Track & Trace Carton Bundle (3.1 s) → Acute Hospital Pharmacies.SUPPLIERHeparin APISupplierI1.40 d10.22um RedundantFiltrationC/T 2.6 sI2.20 d2VialWash-Tunnel-Fill-StopperC/T 4.2 sI1.30 d3Steam TerminalSterilizationC/T 3.0 sI1.00 d4Optical ParticleCamera ScanC/T 2.5 sI2.40 d5Track & TraceCarton BundleC/T 3.1 sI1.50 dCUSTOMERAcute HospitalPharmacies14,000 / vials

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 0.22um Redundant Filtration2.6 s45 min95%99.4%14,00019,600 (1.40 d)18,632
2. Vial Wash-Tunnel-Fill-Stopper4.2 s95 min82%95.8%14,00030,800 (2.20 d)9,034
3. Steam Terminal Sterilization3.0 s25 min92%96.8%7,00018,200 (1.30 d)15,140
4. Optical Particle Camera Scan2.5 s20 min95%99.1%5,60014,000 (1.00 d)19,206
5. Track & Trace Carton Bundle3.1 s10 min93%98.5%14,00033,600 (2.40 d)15,780

Key figures

Takt time
3.9 s
Lead time
9.80 d
Value-added time
15.4 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
90.0%
Customer demand per day
14,000 vials
Line capacity per day
9,034 vials
Bottleneck
Vial Wash-Tunnel-Fill-Stopper

Reading the bottleneck

The bottleneck is "Vial Wash-Tunnel-Fill-Stopper": it can process 9,034 vials per day against a demand of 14,000 vials, so it falls short of demand by 35.5%. Once downtime and scrap are counted, its cycle time grows from 4.2 s to 5.3 s, against a takt of 3.9 s. The largest loss at this step is equipment downtime (uptime 82%), about 0.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Sterile Injectable & Aseptic GMP: Sterile Injectable & Aseptic GMP