Rural 5G Fixed-Wireless (FWA) Outdoor CPE Setup

Product family: Same-Week Countryside Broadband.

Flow: Fixed-Wireless Outdoor CPE → Coverage Signal Qualification → Gable Mount & Cat6 Entry Seal → 5G NR Tower Beam Aiming → Mesh Wi-Fi Coverage Walk → Subscriber Speedtest Sign → Unserved Rural Households

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Rural 5G Fixed-Wireless (FWA) Outdoor CPE SetupSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Fixed-Wireless Outdoor CPE → Coverage Signal Qualification (167 s) → Gable Mount & Cat6 Entry Seal (191 s) → 5G NR Tower Beam Aiming (265 s) → Mesh Wi-Fi Coverage Walk (177 s) → Subscriber Speedtest Sign (110 s) → Unserved Rural Households.SUPPLIERFixed-WirelessOutdoor CPEI2.00 d1Coverage SignalQualificationC/T 167 sI1.80 d2Gable Mount &Cat6 Entry SealC/T 191 sI2.60 d35G NR Tower BeamAimingC/T 265 sI0.80 d4Mesh Wi-FiCoverage WalkC/T 177 sI0.40 d5SubscriberSpeedtest SignC/T 110 sI0.50 dCUSTOMERUnserved RuralHouseholds110 / lines

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Coverage Signal Qualification167 s5 min95%93.0%33220 (2.00 d)138
2. Gable Mount & Cat6 Entry Seal191 s15 min92%95.8%44198 (1.80 d)114
3. 5G NR Tower Beam Aiming265 s20 min84%91.0%33286 (2.60 d)66
4. Mesh Wi-Fi Coverage Walk177 s5 min95%96.8%1788 (0.80 d)130
5. Subscriber Speedtest Sign110 s2 min99%99.1%1144 (0.40 d)230

Key figures

Takt time
245 s
Lead time
8.13 d
Value-added time
910 s
Process cycle efficiency (PCE)
0.41%
Rolled throughput yield (RTY)
77.8%
Customer demand per day
110 lines
Line capacity per day
66 lines
Bottleneck
5G NR Tower Beam Aiming

Reading the bottleneck

The bottleneck is "5G NR Tower Beam Aiming": it can process 66 lines per day against a demand of 110 lines, so it falls short of demand by 39.7%. Once downtime and scrap are counted, its cycle time grows from 265 s to 347 s, against a takt of 245 s. The largest loss at this step is equipment downtime (uptime 84%), about 50.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Telecom Networks, Fiber FTTH & 5G: Telecom Networks, Fiber FTTH & 5G