100-Ton/Day Combed Ring-Spun Organic Cotton Mill

Product family: Ne 40/1 Compact Yarn Cones.

Flow: GOTS Organic Cotton Bales → Auto Bale Pluck & Blowroom → High-Speed Card & Comber → Compact Ring Spinning Frame → Auto-Coner Yarn Clearer → Evenness & Steam Fix → Circular Knit & Denim Mills

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 100-Ton/Day Combed Ring-Spun Organic Cotton MillSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. GOTS Organic Cotton Bales → Auto Bale Pluck & Blowroom (667 s) → High-Speed Card & Comber (800 s) → Compact Ring Spinning Frame (1,029 s) → Auto-Coner Yarn Clearer (724 s) → Evenness & Steam Fix (534 s) → Circular Knit & Denim Mills.SUPPLIERGOTS OrganicCotton BalesI1.60 d1Auto Bale Pluck &BlowroomC/T 667 sI1.80 d2High-Speed Card &ComberC/T 800 sI2.20 d3Compact RingSpinning FrameC/T 1,029 sI1.20 d4Auto-Coner YarnClearerC/T 724 sI0.91 d5Evenness & SteamFixC/T 534 sI1.80 dCUSTOMERCircular Knit &Denim Mills85 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Auto Bale Pluck & Blowroom667 s35 min94%98.8%128136 (1.60 d)111
2. High-Speed Card & Comber800 s55 min90%97.4%128153 (1.80 d)86
3. Compact Ring Spinning Frame1,029 s60 min84%94.8%102187 (2.20 d)60
4. Auto-Coner Yarn Clearer724 s25 min93%98.2%51102 (1.20 d)99
5. Evenness & Steam Fix534 s10 min97%99.1%3477 (0.91 d)143

Key figures

Takt time
953 s
Lead time
9.55 d
Value-added time
3,754 s
Process cycle efficiency (PCE)
0.49%
Rolled throughput yield (RTY)
88.8%
Customer demand per day
85 tonnes
Line capacity per day
60 tonnes
Bottleneck
Compact Ring Spinning Frame

Reading the bottleneck

The bottleneck is "Compact Ring Spinning Frame": it can process 60 tonnes per day against a demand of 85 tonnes, so it falls short of demand by 29.0%. Once downtime and scrap are counted, its cycle time grows from 1,029 s to 1,292 s, against a takt of 953 s. The largest loss at this step is equipment downtime (uptime 84%), about 196 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Spinning, Weaving, Dyeing & Tech Textiles: Spinning, Weaving, Dyeing & Tech Textiles