Split-Bicomponent Warp-Knit Microfiber Roll

Product family: Cleanroom Optics Wiping Cloths.

Flow: 70/30 PET-PA Micro-Filaments → Tricot Warp Knit → Alkaline Fiber Split Shrinkage → Laser Sealed-Edge Ultrasonic → DI-Water Class-100 Launder → Particle Shake Count Packaging → Semicon & Cleanroom Supply

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Split-Bicomponent Warp-Knit Microfiber RollSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 70/30 PET-PA Micro-Filaments → Tricot Warp Knit (788 s) → Alkaline Fiber Split Shrinkage (945 s) → Laser Sealed-Edge Ultrasonic (1,215 s) → DI-Water Class-100 Launder (855 s) → Particle Shake Count Packaging (630 s) → Semicon & Cleanroom Supply.SUPPLIER70/30 PET-PAMicro-FilamentsI1.60 d1Tricot Warp KnitC/T 788 sI1.79 d2Alkaline FiberSplit ShrinkageC/T 945 sI2.21 d3Laser Sealed-EdgeUltrasonicC/T 1,215 sI1.21 d4DI-WaterClass-100 LaunderC/T 855 sI0.90 d5Particle ShakeCount PackagingC/T 630 sI1.79 dCUSTOMERSemicon &Cleanroom…48 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Tricot Warp Knit788 s35 min94%98.8%7277 (1.60 d)62
2. Alkaline Fiber Split Shrinkage945 s55 min90%97.4%7286 (1.79 d)48
3. Laser Sealed-Edge Ultrasonic1,215 s60 min84%94.8%58106 (2.21 d)33
4. DI-Water Class-100 Launder855 s25 min93%98.2%2958 (1.21 d)55
5. Particle Shake Count Packaging630 s10 min97%99.1%1943 (0.90 d)80

Key figures

Takt time
1,125 s
Lead time
9.58 d
Value-added time
4,433 s
Process cycle efficiency (PCE)
0.86%
Rolled throughput yield (RTY)
88.8%
Customer demand per day
48 tonnes
Line capacity per day
33 tonnes
Bottleneck
Laser Sealed-Edge Ultrasonic

Reading the bottleneck

The bottleneck is "Laser Sealed-Edge Ultrasonic": it can process 33 tonnes per day against a demand of 48 tonnes, so it falls short of demand by 30.3%. Once downtime and scrap are counted, its cycle time grows from 1,215 s to 1,526 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 84%), about 231 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Spinning, Weaving, Dyeing & Tech Textiles: Spinning, Weaving, Dyeing & Tech Textiles