Automated In-Ovo Vaccine & Day-Old Chick Hatchery

Product family: 100k/Day Day-Old Chicks.

Flow: Parent Breeder Egg Farms → Egg Setter 18-Day Microclimate → Infrared Fertility & In-Ovo Jab → 3-Day Hatcher Basket Emergence → Automated Sexing & Spray Vac → Climate Chick Bus Delivery → Broiler Grow-Out Barns

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automated In-Ovo Vaccine & Day-Old Chick HatcherySupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Parent Breeder Egg Farms → Egg Setter 18-Day Microclimate (149 s) → Infrared Fertility & In-Ovo Jab (185 s) → 3-Day Hatcher Basket Emergence (241 s) → Automated Sexing & Spray Vac (162 s) → Climate Chick Bus Delivery (122 s) → Broiler Grow-Out Barns.SUPPLIERParent BreederEgg FarmsI0.90 d1Egg Setter 18-DayMicroclimateC/T 149 sI1.20 d2InfraredFertility &…C/T 185 sI1.00 d33-Day HatcherBasket EmergenceC/T 241 sI0.50 d4Automated Sexing& Spray VacC/T 162 sI0.40 d5Climate Chick BusDeliveryC/T 122 sI0.50 dCUSTOMERBroilerGrow-Out Barns240 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Egg Setter 18-Day Microclimate149 s12 min95%97.8%120216 (0.90 d)328
2. Infrared Fertility & In-Ovo Jab185 s15 min93%96.8%120288 (1.20 d)254
3. 3-Day Hatcher Basket Emergence241 s25 min85%94.5%72240 (1.00 d)163
4. Automated Sexing & Spray Vac162 s6 min96%98.8%48120 (0.50 d)306
5. Climate Chick Bus Delivery122 s8 min97%99.4%4896 (0.40 d)408

Key figures

Takt time
225 s
Lead time
4.52 d
Value-added time
859 s
Process cycle efficiency (PCE)
0.35%
Rolled throughput yield (RTY)
87.9%
Customer demand per day
240 crates
Line capacity per day
163 crates
Bottleneck
3-Day Hatcher Basket Emergence

Reading the bottleneck

The bottleneck is "3-Day Hatcher Basket Emergence": it can process 163 crates per day against a demand of 240 crates, so it falls short of demand by 32.0%. Once downtime and scrap are counted, its cycle time grows from 241 s to 300 s, against a takt of 225 s. The largest loss at this step is equipment downtime (uptime 85%), about 42.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hydroponics, Aquaculture & Livestock Ops: Hydroponics, Aquaculture & Livestock Ops