Medjool Date Ultrasonic Mist & Window Box Line

Product family: 1kg Luxury Export Dates.

Flow: Desert Palm Groves → -18°C Thermal Shock Disinfest → Vacuum Moisture Equilibration → NIR Loose-Skin & Weight Sizer → Hand/Robot Orient in Tray → Cellophane Seal & Gold Box → Middle East & EU Grocers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Medjool Date Ultrasonic Mist & Window Box LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Desert Palm Groves → -18°C Thermal Shock Disinfest (10.8 s) → Vacuum Moisture Equilibration (13.2 s) → NIR Loose-Skin & Weight Sizer (18.1 s) → Hand/Robot Orient in Tray (13.8 s) → Cellophane Seal & Gold Box (9.5 s) → Middle East & EU Grocers.SUPPLIERDesert PalmGrovesI0.80 d1-18°C ThermalShock DisinfestC/T 10.8 sI0.70 d2Vacuum MoistureEquilibrationC/T 13.2 sI1.20 d3NIR Loose-Skin &Weight SizerC/T 18.1 sI0.90 d4Hand/Robot Orientin TrayC/T 13.8 sI0.60 d5Cellophane Seal &Gold BoxC/T 9.5 sI0.70 dCUSTOMERMiddle East &EU Grocers3,200 / packs

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. -18°C Thermal Shock Disinfest10.8 s15 min94%97.8%1,6002,560 (0.80 d)4,443
2. Vacuum Moisture Equilibration13.2 s12 min93%98.4%1,2802,240 (0.70 d)3,619
3. NIR Loose-Skin & Weight Sizer18.1 s28 min84%93.0%1,9203,840 (1.20 d)2,210
4. Hand/Robot Orient in Tray13.8 s10 min93%98.4%9602,880 (0.90 d)3,448
5. Cellophane Seal & Gold Box9.5 s8 min97%99.2%9601,920 (0.60 d)5,308

Key figures

Takt time
16.9 s
Lead time
4.90 d
Value-added time
65.4 s
Process cycle efficiency (PCE)
0.025%
Rolled throughput yield (RTY)
87.4%
Customer demand per day
3,200 packs
Line capacity per day
2,210 packs
Bottleneck
NIR Loose-Skin & Weight Sizer

Reading the bottleneck

The bottleneck is "NIR Loose-Skin & Weight Sizer": it can process 2,210 packs per day against a demand of 3,200 packs, so it falls short of demand by 30.9%. Once downtime and scrap are counted, its cycle time grows from 18.1 s to 23.2 s, against a takt of 16.9 s. The largest loss at this step is equipment downtime (uptime 84%), about 3.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Agri-Food Harvest & Export Packhouses: Agri-Food Harvest & Export Packhouses