Polymer-Coated Controlled-Release Urea Prill

Product family: 90-Day Sulfur/PU Slow-Release.

Flow: Prilled Granular Urea 46% → Pre-Heat 75°C Rotary Drum → Multi-Spray MDI/Polyol React → Anti-Static Wax Topcoat → 24h Water Leach Curve Audit → 25kg Bag & Container Bulk → Turf, Rice & Orchard Growers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Polymer-Coated Controlled-Release Urea PrillSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Prilled Granular Urea 46% → Pre-Heat 75°C Rotary Drum (648 s) → Multi-Spray MDI/Polyol React (810 s) → Anti-Static Wax Topcoat (1,010 s) → 24h Water Leach Curve Audit (686 s) → 25kg Bag & Container Bulk (553 s) → Turf, Rice & Orchard Growers.SUPPLIERPrilledGranular Urea46%I1.60 d1Pre-Heat 75°CRotary DrumC/T 648 sI1.80 d2Multi-SprayMDI/Polyol ReactC/T 810 sI2.00 d3Anti-Static WaxTopcoatC/T 1,010 sI1.00 d424h Water LeachCurve AuditC/T 686 sI1.20 d525kg Bag &Container BulkC/T 553 sI2.20 dCUSTOMERTurf, Rice &Orchard Growers85 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Pre-Heat 75°C Rotary Drum648 s30 min94%98.8%128136 (1.60 d)114
2. Multi-Spray MDI/Polyol React810 s45 min90%97.4%128153 (1.80 d)86
3. Anti-Static Wax Topcoat1,010 s35 min84%95.8%85170 (2.00 d)63
4. 24h Water Leach Curve Audit686 s10 min95%98.5%3485 (1.00 d)108
5. 25kg Bag & Container Bulk553 s15 min96%99.3%43102 (1.20 d)137

Key figures

Takt time
953 s
Lead time
9.85 d
Value-added time
3,707 s
Process cycle efficiency (PCE)
0.46%
Rolled throughput yield (RTY)
90.2%
Customer demand per day
85 tonnes
Line capacity per day
63 tonnes
Bottleneck
Anti-Static Wax Topcoat

Reading the bottleneck

The bottleneck is "Anti-Static Wax Topcoat": it can process 63 tonnes per day against a demand of 85 tonnes, so it falls short of demand by 26.0%. Once downtime and scrap are counted, its cycle time grows from 1,010 s to 1,255 s, against a takt of 953 s. The largest loss at this step is equipment downtime (uptime 84%), about 192 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Agrochemicals, Fertilizers & Bio-Inputs: Agrochemicals, Fertilizers & Bio-Inputs