99.8% Isostatic Technical Alumina Ceramics

Product family: Extreme-Temp Wear Components.

Flow: Calcined Alumina Producer → Spray Dry & Cold Isostatic Press → Green Diamond Lathe Turn → 1750°C Gas Sinter Shrinkage → Diamond Surface Grind → Ultrasonic Pinhole & CMM → Semicon & Metallurgy OEMs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 99.8% Isostatic Technical Alumina CeramicsSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Calcined Alumina Producer → Spray Dry & Cold Isostatic Press (77.0 s) → Green Diamond Lathe Turn (97.0 s) → 1750°C Gas Sinter Shrinkage (120 s) → Diamond Surface Grind (88.0 s) → Ultrasonic Pinhole & CMM (68.0 s) → Semicon & Metallurgy OEMs.SUPPLIERCalcinedAluminaProducerI1.60 d1Spray Dry & ColdIsostatic PressC/T 77.0 sI1.40 d2Green DiamondLathe TurnC/T 97.0 sI2.20 d31750°C Gas SinterShrinkageC/T 120 sI1.30 d4Diamond SurfaceGrindC/T 88.0 sI1.10 d5UltrasonicPinhole & CMMC/T 68.0 sI2.00 dCUSTOMERSemicon &Metallurgy OEMs480 / parts

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Spray Dry & Cold Isostatic Press77.0 s20 min96%99.1%720768 (1.60 d)657
2. Green Diamond Lathe Turn97.0 s40 min95%97.6%720672 (1.40 d)501
3. 1750°C Gas Sinter Shrinkage120 s45 min84%94.8%4801,056 (2.20 d)340
4. Diamond Surface Grind88.0 s20 min92%97.8%288624 (1.30 d)532
5. Ultrasonic Pinhole & CMM68.0 s10 min97%99.2%240528 (1.10 d)747

Key figures

Takt time
113 s
Lead time
9.61 d
Value-added time
450 s
Process cycle efficiency (PCE)
0.087%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
480 parts
Line capacity per day
340 parts
Bottleneck
1750°C Gas Sinter Shrinkage

Reading the bottleneck

The bottleneck is "1750°C Gas Sinter Shrinkage": it can process 340 parts per day against a demand of 480 parts, so it falls short of demand by 29.1%. Once downtime and scrap are counted, its cycle time grows from 120 s to 151 s, against a takt of 113 s. The largest loss at this step is equipment downtime (uptime 84%), about 22.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Glass, Ceramics & Mineral Wool: Glass, Ceramics & Mineral Wool