Recycled-Glass Fiberglass Insulation Batt Line

Product family: λ=0.032 Thermal Acoustic Rolls.

Flow: 80% Recycled Window Cullet → Electric Melter Furnace 1450°C → High-RPM Spinner Fiberize → Formaldehyde-Free Resin Cure → High-Compression Roll Slitter → 5:1 Vacuum Multi-Pack Compress → Building Insulation Merchants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Recycled-Glass Fiberglass Insulation Batt LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 80% Recycled Window Cullet → Electric Melter Furnace 1450°C (501 s) → High-RPM Spinner Fiberize (633 s) → Formaldehyde-Free Resin Cure (788 s) → High-Compression Roll Slitter (574 s) → 5:1 Vacuum Multi-Pack Compress (442 s) → Building Insulation Merchants.SUPPLIER80% RecycledWindow CulletI1.60 d1Electric MelterFurnace 1450°CC/T 501 sI1.40 d2High-RPM SpinnerFiberizeC/T 633 sI2.20 d3Formaldehyde-FreeResin CureC/T 788 sI1.30 d4High-CompressionRoll SlitterC/T 574 sI1.10 d55:1 VacuumMulti-Pack…C/T 442 sI2.00 dCUSTOMERBuildingInsulation…110 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Electric Melter Furnace 1450°C501 s20 min96%99.1%165176 (1.60 d)152
2. High-RPM Spinner Fiberize633 s40 min95%97.6%165154 (1.40 d)116
3. Formaldehyde-Free Resin Cure788 s45 min84%94.8%110242 (2.20 d)79
4. High-Compression Roll Slitter574 s20 min92%97.8%66143 (1.30 d)124
5. 5:1 Vacuum Multi-Pack Compress442 s10 min97%99.2%55121 (1.10 d)174

Key figures

Takt time
736 s
Lead time
9.64 d
Value-added time
2,938 s
Process cycle efficiency (PCE)
0.38%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
110 tonnes
Line capacity per day
79 tonnes
Bottleneck
Formaldehyde-Free Resin Cure

Reading the bottleneck

The bottleneck is "Formaldehyde-Free Resin Cure": it can process 79 tonnes per day against a demand of 110 tonnes, so it falls short of demand by 28.1%. Once downtime and scrap are counted, its cycle time grows from 788 s to 990 s, against a takt of 736 s. The largest loss at this step is equipment downtime (uptime 84%), about 150 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Glass, Ceramics & Mineral Wool: Glass, Ceramics & Mineral Wool