1550°C Basalt Rockwool Fire-Barrier Slab Line

Product family: A1 Non-Combustible Stone Wool.

Flow: Basalt Quarry & Steel Slag → Coke/Electric Cupola Melt → 4-Wheel Cascade Fiber Spin → Pendulum Fleece & Crimping → Phenolic Curing Oven 240°C → Saw Trim & Hood Shrink Pack → Cladding & Marine Fire Doors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 1550°C Basalt Rockwool Fire-Barrier Slab LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Basalt Quarry & Steel Slag → Coke/Electric Cupola Melt (393 s) → 4-Wheel Cascade Fiber Spin (498 s) → Pendulum Fleece & Crimping (619 s) → Phenolic Curing Oven 240°C (451 s) → Saw Trim & Hood Shrink Pack (347 s) → Cladding & Marine Fire Doors.SUPPLIERBasalt Quarry &Steel SlagI1.60 d1Coke/ElectricCupola MeltC/T 393 sI1.40 d24-Wheel CascadeFiber SpinC/T 498 sI2.20 d3Pendulum Fleece &CrimpingC/T 619 sI1.30 d4Phenolic CuringOven 240°CC/T 451 sI1.10 d5Saw Trim & HoodShrink PackC/T 347 sI2.00 dCUSTOMERCladding &Marine Fire…140 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Coke/Electric Cupola Melt393 s20 min96%99.1%210224 (1.60 d)194
2. 4-Wheel Cascade Fiber Spin498 s40 min95%97.6%210196 (1.40 d)148
3. Pendulum Fleece & Crimping619 s45 min84%94.8%140308 (2.20 d)101
4. Phenolic Curing Oven 240°C451 s20 min92%97.8%84182 (1.30 d)158
5. Saw Trim & Hood Shrink Pack347 s10 min97%99.2%70154 (1.10 d)221

Key figures

Takt time
579 s
Lead time
9.63 d
Value-added time
2,308 s
Process cycle efficiency (PCE)
0.30%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
140 tonnes
Line capacity per day
101 tonnes
Bottleneck
Pendulum Fleece & Crimping

Reading the bottleneck

The bottleneck is "Pendulum Fleece & Crimping": it can process 101 tonnes per day against a demand of 140 tonnes, so it falls short of demand by 28.1%. Once downtime and scrap are counted, its cycle time grows from 619 s to 777 s, against a takt of 579 s. The largest loss at this step is equipment downtime (uptime 84%), about 118 s per unit. Reducing that loss is where the first improvement test belongs.