Vertical Twin-Shaft Regenerative Quicklime Kiln

Product family: 95% Reactive CaO Industrial Lime.

Flow: High-Purity Calcium Quarry → Wash Screen & Skip Hoist Charge → PFR Twin-Shaft 1100°C Calciner → Hydrator Slaking / Milling → Silica-Free Sieve Classify → Bulk Silo & Pneumatic Load → Steel Mills, Water & AAC

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Vertical Twin-Shaft Regenerative Quicklime KilnSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. High-Purity Calcium Quarry → Wash Screen & Skip Hoist Charge (100 s) → PFR Twin-Shaft 1100°C Calciner (167 s) → Hydrator Slaking / Milling (125 s) → Silica-Free Sieve Classify (106 s) → Bulk Silo & Pneumatic Load (81.0 s) → Steel Mills, Water & AAC.SUPPLIERHigh-PurityCalcium QuarryI1.40 d1Wash Screen &Skip Hoist ChargeC/T 100 sI1.80 d2PFR Twin-Shaft1100°C CalcinerC/T 167 sI1.20 d3Hydrator Slaking/ MillingC/T 125 sI0.70 d4Silica-Free SieveClassifyC/T 106 sI0.80 d5Bulk Silo &Pneumatic LoadC/T 81.0 sI1.20 dCUSTOMERSteel Mills,Water & AAC520 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Wash Screen & Skip Hoist Charge100 s20 min95%99.1%624728 (1.40 d)753
2. PFR Twin-Shaft 1100°C Calciner167 s45 min84%96.4%780936 (1.80 d)384
3. Hydrator Slaking / Milling125 s15 min93%98.4%416624 (1.20 d)585
4. Silica-Free Sieve Classify106 s5 min96%98.8%156364 (0.70 d)716
5. Bulk Silo & Pneumatic Load81.0 s8 min97%99.5%130416 (0.80 d)942

Key figures

Takt time
156 s
Lead time
7.11 d
Value-added time
579 s
Process cycle efficiency (PCE)
0.10%
Rolled throughput yield (RTY)
92.4%
Customer demand per day
520 tonnes
Line capacity per day
384 tonnes
Bottleneck
PFR Twin-Shaft 1100°C Calciner

Reading the bottleneck

The bottleneck is "PFR Twin-Shaft 1100°C Calciner": it can process 384 tonnes per day against a demand of 520 tonnes, so it falls short of demand by 26.1%. Once downtime and scrap are counted, its cycle time grows from 167 s to 206 s, against a takt of 156 s. The largest loss at this step is equipment downtime (uptime 84%), about 31.8 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cement, Concrete, Bricks & Materials: Cement, Concrete, Bricks & Materials