Fiber-Cement Autoclaved Architectural Cladding

Product family: Through-Colored Rainscreen.

Flow: Cellulose, Silica & Cement → Hatschek Multi-Vat Sieve Film → Accumulator Roll Stack Press → 180°C Autoclave Cure Harden → Diamond Cut & UV Acrylic Coat → Interleaved Crated Stack → Commercial Cladding Sites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Fiber-Cement Autoclaved Architectural CladdingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Cellulose, Silica & Cement → Hatschek Multi-Vat Sieve Film (14.4 s) → Accumulator Roll Stack Press (24.1 s) → 180°C Autoclave Cure Harden (18.0 s) → Diamond Cut & UV Acrylic Coat (15.3 s) → Interleaved Crated Stack (11.7 s) → Commercial Cladding Sites.SUPPLIERCellulose,Silica & CementI1.40 d1HatschekMulti-Vat Sieve…C/T 14.4 sI1.80 d2Accumulator RollStack PressC/T 24.1 sI1.20 d3180°C AutoclaveCure HardenC/T 18.0 sI0.70 d4Diamond Cut & UVAcrylic CoatC/T 15.3 sI0.80 d5InterleavedCrated StackC/T 11.7 sI1.20 dCUSTOMERCommercialCladding Sites2,400 / parts

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Hatschek Multi-Vat Sieve Film14.4 s20 min95%99.1%2,8803,360 (1.40 d)3,465
2. Accumulator Roll Stack Press24.1 s45 min84%96.4%3,6004,320 (1.80 d)1,754
3. 180°C Autoclave Cure Harden18.0 s15 min93%98.4%1,9202,880 (1.20 d)2,688
4. Diamond Cut & UV Acrylic Coat15.3 s5 min96%98.8%7201,680 (0.70 d)3,286
5. Interleaved Crated Stack11.7 s8 min97%99.5%6001,920 (0.80 d)4,296

Key figures

Takt time
22.5 s
Lead time
7.10 d
Value-added time
83.5 s
Process cycle efficiency (PCE)
0.022%
Rolled throughput yield (RTY)
92.4%
Customer demand per day
2,400 parts
Line capacity per day
1,754 parts
Bottleneck
Accumulator Roll Stack Press

Reading the bottleneck

The bottleneck is "Accumulator Roll Stack Press": it can process 1,754 parts per day against a demand of 2,400 parts, so it falls short of demand by 26.9%. Once downtime and scrap are counted, its cycle time grows from 24.1 s to 29.8 s, against a takt of 22.5 s. The largest loss at this step is equipment downtime (uptime 84%), about 4.6 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cement, Concrete, Bricks & Materials: Cement, Concrete, Bricks & Materials