ISO-15197 Connected Bluetooth Blood Glucometer

Product family: Pocket Amperometric Readers.

Flow: Analog Front-End Chips → Medical ABS Shell Molding → Low-Leakage Strip Socket SMT → LCD Glass & Elastomer Pad → Control Strip Precision Calib → ISO Accuracy Lot Verify → Pharmacy & Diabetes Care

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: ISO-15197 Connected Bluetooth Blood GlucometerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Analog Front-End Chips → Medical ABS Shell Molding (8.2 s) → Low-Leakage Strip Socket SMT (10.8 s) → LCD Glass & Elastomer Pad (13.8 s) → Control Strip Precision Calib (9.5 s) → ISO Accuracy Lot Verify (7.2 s) → Pharmacy & Diabetes Care.SUPPLIERAnalogFront-End ChipsI1.30 d1Medical ABS ShellMoldingC/T 8.2 sI1.20 d2Low-Leakage StripSocket SMTC/T 10.8 sI1.60 d3LCD Glass &Elastomer PadC/T 13.8 sI0.90 d4Control StripPrecision CalibC/T 9.5 sI0.70 d5ISO Accuracy LotVerifyC/T 7.2 sI1.50 dCUSTOMERPharmacy &Diabetes Care4,200 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Medical ABS Shell Molding8.2 s15 min96%98.9%2,5205,460 (1.30 d)6,079
2. Low-Leakage Strip Socket SMT10.8 s12 min93%97.6%1,2605,040 (1.20 d)4,337
3. LCD Glass & Elastomer Pad13.8 s15 min86%95.2%1,0506,720 (1.60 d)2,990
4. Control Strip Precision Calib9.5 s8 min95%98.8%1,0503,780 (0.90 d)5,146
5. ISO Accuracy Lot Verify7.2 s6 min98%99.6%8402,940 (0.70 d)7,077

Key figures

Takt time
12.9 s
Lead time
7.20 d
Value-added time
49.5 s
Process cycle efficiency (PCE)
0.013%
Rolled throughput yield (RTY)
90.4%
Customer demand per day
4,200 units
Line capacity per day
2,990 units
Bottleneck
LCD Glass & Elastomer Pad

Reading the bottleneck

The bottleneck is "LCD Glass & Elastomer Pad": it can process 2,990 units per day against a demand of 4,200 units, so it falls short of demand by 28.8%. Once downtime and scrap are counted, its cycle time grows from 13.8 s to 16.9 s, against a takt of 12.9 s. The largest loss at this step is equipment downtime (uptime 86%), about 2.2 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Smart Devices, POS & Wearables: Smart Devices, POS & Wearables