Matter Wi-Fi Aluminum Smart HVAC Thermostat

Product family: Rotary Dial Building Controls.

Flow: Turned Anodized Al Rings → CNC Anodized Dial Encoder → Temp/Humidity/VOC Sensor Cal → 24VAC Triac Relay Backplate → Automated RF Pairing Rig → Relay Surge & Gift Box → Utility & Home Installers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Matter Wi-Fi Aluminum Smart HVAC ThermostatSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Turned Anodized Al Rings → CNC Anodized Dial Encoder (15.7 s) → Temp/Humidity/VOC Sensor Cal (20.6 s) → 24VAC Triac Relay Backplate (26.3 s) → Automated RF Pairing Rig (18.2 s) → Relay Surge & Gift Box (13.7 s) → Utility & Home Installers.SUPPLIERTurned AnodizedAl RingsI1.30 d1CNC Anodized DialEncoderC/T 15.7 sI1.20 d2Temp/Humidity/VOCSensor CalC/T 20.6 sI1.60 d324VAC Triac RelayBackplateC/T 26.3 sI0.90 d4Automated RFPairing RigC/T 18.2 sI0.70 d5Relay Surge &Gift BoxC/T 13.7 sI1.50 dCUSTOMERUtility & HomeInstallers2,200 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. CNC Anodized Dial Encoder15.7 s15 min96%98.9%1,3202,860 (1.30 d)3,175
2. Temp/Humidity/VOC Sensor Cal20.6 s12 min93%97.6%6602,640 (1.20 d)2,274
3. 24VAC Triac Relay Backplate26.3 s15 min86%95.2%5503,520 (1.60 d)1,569
4. Automated RF Pairing Rig18.2 s8 min95%98.8%5501,980 (0.90 d)2,686
5. Relay Surge & Gift Box13.7 s6 min98%99.6%4401,540 (0.70 d)3,719

Key figures

Takt time
24.5 s
Lead time
7.20 d
Value-added time
94.5 s
Process cycle efficiency (PCE)
0.024%
Rolled throughput yield (RTY)
90.4%
Customer demand per day
2,200 units
Line capacity per day
1,569 units
Bottleneck
24VAC Triac Relay Backplate

Reading the bottleneck

The bottleneck is "24VAC Triac Relay Backplate": it can process 1,569 units per day against a demand of 2,200 units, so it falls short of demand by 28.7%. Once downtime and scrap are counted, its cycle time grows from 26.3 s to 32.1 s, against a takt of 24.5 s. The largest loss at this step is equipment downtime (uptime 86%), about 4.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Smart Devices, POS & Wearables: Smart Devices, POS & Wearables