4K Chip-on-Tip Surgical Laparoscope Optics

Product family: Autoclavable Medical Scopes.

Flow: Imaging Fiber & CMOS Sensor Suppliers → Sapphire Tip Gold Brazing → Micro CMOS Active Lens Gluing → Optical Illumination Fiber Pack → Laser Titanium Seam Seal → 50-Cycle Steam Autoclave QC → Hospital Endoscopy Units

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 4K Chip-on-Tip Surgical Laparoscope OpticsSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Imaging Fiber & CMOS Sensor Suppliers → Sapphire Tip Gold Brazing (299 s) → Micro CMOS Active Lens Gluing (349 s) → Optical Illumination Fiber Pack (449 s) → Laser Titanium Seam Seal (316 s) → 50-Cycle Steam Autoclave QC (249 s) → Hospital Endoscopy Units.SUPPLIERImaging Fiber &CMOS SensorSuppliersI1.80 d1Sapphire Tip GoldBrazingC/T 299 sI1.91 d2Micro CMOS ActiveLens GluingC/T 349 sI2.11 d3OpticalIllumination…C/T 449 sI1.00 d4Laser TitaniumSeam SealC/T 316 sI0.71 d550-Cycle SteamAutoclave QCC/T 249 sI1.20 dCUSTOMERHospitalEndoscopy Units65 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Sapphire Tip Gold Brazing299 s30 min94%97.8%65117 (1.80 d)77
2. Micro CMOS Active Lens Gluing349 s45 min90%96.5%78124 (1.91 d)62
3. Optical Illumination Fiber Pack449 s25 min84%93.8%33137 (2.11 d)42
4. Laser Titanium Seam Seal316 s15 min95%98.4%2065 (1.00 d)71
5. 50-Cycle Steam Autoclave QC249 s8 min97%99.1%1346 (0.71 d)95

Key figures

Takt time
415 s
Lead time
8.78 d
Value-added time
1,662 s
Process cycle efficiency (PCE)
0.70%
Rolled throughput yield (RTY)
86.3%
Customer demand per day
65 units
Line capacity per day
42 units
Bottleneck
Optical Illumination Fiber Pack

Reading the bottleneck

The bottleneck is "Optical Illumination Fiber Pack": it can process 42 units per day against a demand of 65 units, so it falls short of demand by 35.1%. Once downtime and scrap are counted, its cycle time grows from 449 s to 570 s, against a takt of 415 s. The largest loss at this step is equipment downtime (uptime 84%), about 85.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.