40Gbps Cat8 S/FTP Data Center Patch Trunk

Product family: LSZH Foil-Shielded Copper Trunks.

Flow: OFHC Bare Copper Wire → Dual Gas-Injected Skin-Foam → High-Speed Pair Twinning → Al Foil Wrap & 4-Pair Braid → LSZH Jacket & RJ45 Crimp → Cable Analyzer 2GHz Sweep Pass → Hyperscale Switch Fabrics

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 40Gbps Cat8 S/FTP Data Center Patch TrunkSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. OFHC Bare Copper Wire → Dual Gas-Injected Skin-Foam (26.2 s) → High-Speed Pair Twinning (31.6 s) → Al Foil Wrap & 4-Pair Braid (41.0 s) → LSZH Jacket & RJ45 Crimp (30.1 s) → Cable Analyzer 2GHz Sweep Pass (23.1 s) → Hyperscale Switch Fabrics.SUPPLIEROFHC BareCopper WireI1.60 d1Dual Gas-InjectedSkin-FoamC/T 26.2 sI1.80 d2High-Speed PairTwinningC/T 31.6 sI2.40 d3Al Foil Wrap &4-Pair BraidC/T 41.0 sI1.40 d4LSZH Jacket &RJ45 CrimpC/T 30.1 sI0.90 d5Cable Analyzer2GHz Sweep PassC/T 23.1 sI1.80 dCUSTOMERHyperscaleSwitch Fabrics1,400 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Dual Gas-Injected Skin-Foam26.2 s35 min94%99.2%2,1002,240 (1.60 d)1,872
2. High-Speed Pair Twinning31.6 s50 min91%98.5%2,1002,520 (1.80 d)1,475
3. Al Foil Wrap & 4-Pair Braid41.0 s95 min83%96.4%2,8003,360 (2.40 d)998
4. LSZH Jacket & RJ45 Crimp30.1 s30 min93%98.7%1,4001,960 (1.40 d)1,592
5. Cable Analyzer 2GHz Sweep Pass23.1 s12 min97%99.3%7001,260 (0.90 d)2,192

Key figures

Takt time
38.6 s
Lead time
9.90 d
Value-added time
152 s
Process cycle efficiency (PCE)
0.028%
Rolled throughput yield (RTY)
92.3%
Customer demand per day
1,400 units
Line capacity per day
998 units
Bottleneck
Al Foil Wrap & 4-Pair Braid

Reading the bottleneck

The bottleneck is "Al Foil Wrap & 4-Pair Braid": it can process 998 units per day against a demand of 1,400 units, so it falls short of demand by 28.7%. Once downtime and scrap are counted, its cycle time grows from 41.0 s to 51.2 s, against a takt of 38.6 s. The largest loss at this step is equipment downtime (uptime 83%), about 8.4 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.