Captured CO2 + Green H2 e-Methanol Synthesis

Product family: Carbon-Neutral Marine Fuel.

Flow: Biogenic CO2 & Green H2 → 3:1 H2/CO2 Compression Feed → Cu/ZnO Catalytic Loop Reactor → Water Separation Flash Drum → 2-Column Distillation Polish → Methanol Purity Grade & Bunkering → Green Container Shipping

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Captured CO2 + Green H2 e-Methanol SynthesisSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Biogenic CO2 & Green H2 → 3:1 H2/CO2 Compression Feed (501 s) → Cu/ZnO Catalytic Loop Reactor (619 s) → Water Separation Flash Drum (788 s) → 2-Column Distillation Polish (530 s) → Methanol Purity Grade & Bunkering (398 s) → Green Container Shipping.SUPPLIERBiogenic CO2 &Green H2I1.40 d13:1 H2/CO2Compression FeedC/T 501 sI1.60 d2Cu/ZnO CatalyticLoop ReactorC/T 619 sI2.00 d3Water SeparationFlash DrumC/T 788 sI0.90 d42-ColumnDistillation…C/T 530 sI0.70 d5Methanol PurityGrade & BunkeringC/T 398 sI1.20 dCUSTOMERGreen ContainerShipping110 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 3:1 H2/CO2 Compression Feed501 s20 min94%98.2%110154 (1.40 d)147
2. Cu/ZnO Catalytic Loop Reactor619 s30 min91%97.4%110176 (1.60 d)113
3. Water Separation Flash Drum788 s40 min84%95.8%110220 (2.00 d)80
4. 2-Column Distillation Polish530 s10 min96%98.6%4499 (0.90 d)142
5. Methanol Purity Grade & Bunkering398 s8 min97%99.4%3377 (0.70 d)192

Key figures

Takt time
736 s
Lead time
7.84 d
Value-added time
2,836 s
Process cycle efficiency (PCE)
0.45%
Rolled throughput yield (RTY)
89.8%
Customer demand per day
110 tonnes
Line capacity per day
80 tonnes
Bottleneck
Water Separation Flash Drum

Reading the bottleneck

The bottleneck is "Water Separation Flash Drum": it can process 80 tonnes per day against a demand of 110 tonnes, so it falls short of demand by 27.0%. Once downtime and scrap are counted, its cycle time grows from 788 s to 979 s, against a takt of 736 s. The largest loss at this step is equipment downtime (uptime 84%), about 150 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Decarbonization, Green Steel & Circular ESG: Decarbonization, Green Steel & Circular ESG