Direct Air Capture (DAC) Solid-Sorbent CO2 Pod

Product family: Modular Atmospheric Capture.

Flow: Geothermal Heat & Ambient Air → High-Flow Fan CO2 Adsorption → Chamber Vacuum Seal Closure → 100°C Steam Thermal Desorb → CO2 Condense & Water Purge → 150-Bar Supercritical Pipe → Subsurface Basalt Sequestration

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Direct Air Capture (DAC) Solid-Sorbent CO2 PodSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Geothermal Heat & Ambient Air → High-Flow Fan CO2 Adsorption (3,060 s) → Chamber Vacuum Seal Closure (3,780 s) → 100°C Steam Thermal Desorb (4,815 s) → CO2 Condense & Water Purge (3,240 s) → 150-Bar Supercritical Pipe (2,430 s) → Subsurface Basalt Sequestration.SUPPLIERGeothermal Heat& Ambient AirI1.39 d1High-Flow Fan CO2AdsorptionC/T 3,060 sI1.61 d2Chamber VacuumSeal ClosureC/T 3,780 sI2.00 d3100°C SteamThermal DesorbC/T 4,815 sI0.89 d4CO2 Condense &Water PurgeC/T 3,240 sI0.72 d5150-BarSupercritical…C/T 2,430 sI1.22 dCUSTOMERSubsurfaceBasalt…18 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. High-Flow Fan CO2 Adsorption3,060 s20 min94%98.2%1825 (1.39 d)24
2. Chamber Vacuum Seal Closure3,780 s30 min91%97.4%1829 (1.61 d)19
3. 100°C Steam Thermal Desorb4,815 s40 min84%95.8%1836 (2.00 d)13
4. CO2 Condense & Water Purge3,240 s10 min96%98.6%716 (0.89 d)23
5. 150-Bar Supercritical Pipe2,430 s8 min97%99.4%513 (0.72 d)31

Key figures

Takt time
4,500 s
Lead time
8.05 d
Value-added time
17,325 s
Process cycle efficiency (PCE)
2.7%
Rolled throughput yield (RTY)
89.8%
Customer demand per day
18 batches
Line capacity per day
13 batches
Bottleneck
100°C Steam Thermal Desorb

Reading the bottleneck

The bottleneck is "100°C Steam Thermal Desorb": it can process 13 batches per day against a demand of 18 batches, so it falls short of demand by 27.0%. Once downtime and scrap are counted, its cycle time grows from 4,815 s to 5,983 s, against a takt of 4,500 s. The largest loss at this step is equipment downtime (uptime 84%), about 917 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Decarbonization, Green Steel & Circular ESG: Decarbonization, Green Steel & Circular ESG