100% Hydrogen Direct-Reduced Iron (H2-DRI) EAF

Product family: Near-Zero Fossil Flat Steel.

Flow: DR-Grade Pellets & Green H2 → 100% H2 Shaft Furnace Reduc → Hot-Charged EAF Electric Melt → Argon Ladle Secondary Refine → Thin-Slab Continuous Caster → EPD Verified Low-CO2 Coil Tag → Automotive Low-CO2 Coils

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 100% Hydrogen Direct-Reduced Iron (H2-DRI) EAFSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. DR-Grade Pellets & Green H2 → 100% H2 Shaft Furnace Reduc (85.0 s) → Hot-Charged EAF Electric Melt (105 s) → Argon Ladle Secondary Refine (133 s) → Thin-Slab Continuous Caster (90.0 s) → EPD Verified Low-CO2 Coil Tag (67.0 s) → Automotive Low-CO2 Coils.SUPPLIERDR-GradePellets & GreenH2I1.40 d1100% H2 ShaftFurnace ReducC/T 85.0 sI1.60 d2Hot-Charged EAFElectric MeltC/T 105 sI2.00 d3Argon LadleSecondary RefineC/T 133 sI0.90 d4Thin-SlabContinuous CasterC/T 90.0 sI0.70 d5EPD VerifiedLow-CO2 Coil TagC/T 67.0 sI1.20 dCUSTOMERAutomotiveLow-CO2 Coils650 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 100% H2 Shaft Furnace Reduc85.0 s20 min94%98.2%650910 (1.40 d)867
2. Hot-Charged EAF Electric Melt105 s30 min91%97.4%6501,040 (1.60 d)669
3. Argon Ladle Secondary Refine133 s40 min84%95.8%6501,300 (2.00 d)476
4. Thin-Slab Continuous Caster90.0 s10 min96%98.6%260585 (0.90 d)836
5. EPD Verified Low-CO2 Coil Tag67.0 s8 min97%99.4%195455 (0.70 d)1,143

Key figures

Takt time
125 s
Lead time
7.81 d
Value-added time
480 s
Process cycle efficiency (PCE)
0.076%
Rolled throughput yield (RTY)
89.8%
Customer demand per day
650 tonnes
Line capacity per day
476 tonnes
Bottleneck
Argon Ladle Secondary Refine

Reading the bottleneck

The bottleneck is "Argon Ladle Secondary Refine": it can process 476 tonnes per day against a demand of 650 tonnes, so it falls short of demand by 26.8%. Once downtime and scrap are counted, its cycle time grows from 133 s to 165 s, against a takt of 125 s. The largest loss at this step is equipment downtime (uptime 84%), about 25.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Decarbonization, Green Steel & Circular ESG: Decarbonization, Green Steel & Circular ESG