Mass AMI Smart Electricity Meter Swap Route
Product family: 100-Meters/Crew Daily Swap.
Flow: DLMS Smart Meters & Seals → Geo-Routed Appointment Batch → Safety Outage Check & Unseal → DIN Rail Swap & Torque Cover → RF Mesh Ping & Head-End Sync → Old Meter Scrape & Tamper Seal → Distribution Utility Customers
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. Geo-Routed Appointment Batch | 27.4 s | 15 min | 96% | 95.8% | 195 | 1,170 (1.80 d) | 806 |
| 2. Safety Outage Check & Unseal | 32.4 s | 20 min | 93% | 97.6% | 260 | 1,040 (1.60 d) | 672 |
| 3. DIN Rail Swap & Torque Cover | 45.0 s | 30 min | 85% | 94.5% | 195 | 1,430 (2.20 d) | 375 |
| 4. RF Mesh Ping & Head-End Sync | 31.6 s | 12 min | 94% | 97.8% | 130 | 585 (0.90 d) | 681 |
| 5. Old Meter Scrape & Tamper Seal | 20.8 s | 5 min | 98% | 99.4% | 65 | 260 (0.40 d) | 1,124 |
Key figures
- Takt time
- 41.5 s
- Lead time
- 7.41 d
- Value-added time
- 157 s
- Process cycle efficiency (PCE)
- 0.079%
- Rolled throughput yield (RTY)
- 85.9%
- Customer demand per day
- 650 units
- Line capacity per day
- 375 units
- Bottleneck
- DIN Rail Swap & Torque Cover
Reading the bottleneck
The bottleneck is "DIN Rail Swap & Torque Cover": it can process 375 units per day against a demand of 650 units, so it falls short of demand by 42.3%. Once downtime and scrap are counted, its cycle time grows from 45.0 s to 56.0 s, against a takt of 41.5 s. The largest loss at this step is changeovers (30 min every 195 units), about 9.2 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Power Grids, Substations & Smart Metering: Power Grids, Substations & Smart Metering
- 220kV Air-Insulated Grid Substation Bay Build
- 63kV Overhead Aluminum HTLS Reconductoring
- 110kV XLPE Underground Cable Splice & HiPot
- Storm Distribution Feeder Fault Isolation & Restore
- PWR Nuclear Power Plant Refueling Outage (RFO)
- 450MW Gas Turbine Hot-Gas-Path Inspection
- Electric Bus Depot 3MW Grid Transformer Upgrade
- 2GW Offshore HVDC Converter Thyristor Maintenance
- Municipal Streetlight Zhaga-D4i Smart LED Retro
- Substation IEC-61850 Protection Relay Maintenance
- Industrial Islandable Solar+Genset Microgrid