Storm Distribution Feeder Fault Isolation & Restore
Product family: SAIDI <45-Min Auto-Restore.
Flow: ADMS Fault Locator Alerts → ADMS Smart-Meter Outage Ping → FLISR Remote Section Isolate → Crew Patrol & Tree Clear Cut → Live-Line Hotstick Fuse Swap → Backfeed Confirm & Telemetry → Affected Grid Households
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. ADMS Smart-Meter Outage Ping | 1,188 s | 15 min | 96% | 95.8% | 14 | 81 (1.80 d) | 60 |
| 2. FLISR Remote Section Isolate | 1,404 s | 20 min | 93% | 97.6% | 18 | 72 (1.60 d) | 50 |
| 3. Crew Patrol & Tree Clear Cut | 1,944 s | 30 min | 85% | 94.5% | 14 | 99 (2.20 d) | 31 |
| 4. Live-Line Hotstick Fuse Swap | 1,368 s | 12 min | 94% | 97.8% | 9 | 41 (0.91 d) | 52 |
| 5. Backfeed Confirm & Telemetry | 900 s | 5 min | 98% | 99.4% | 5 | 18 (0.40 d) | 85 |
Key figures
- Takt time
- 1,800 s
- Lead time
- 7.51 d
- Value-added time
- 6,804 s
- Process cycle efficiency (PCE)
- 1.1%
- Rolled throughput yield (RTY)
- 85.9%
- Customer demand per day
- 45 cases
- Line capacity per day
- 31 cases
- Bottleneck
- Crew Patrol & Tree Clear Cut
Reading the bottleneck
The bottleneck is "Crew Patrol & Tree Clear Cut": it can process 31 cases per day against a demand of 45 cases, so it falls short of demand by 30.9%. Once downtime and scrap are counted, its cycle time grows from 1,944 s to 2,420 s, against a takt of 1,800 s. The largest loss at this step is equipment downtime (uptime 85%), about 343 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Power Grids, Substations & Smart Metering: Power Grids, Substations & Smart Metering
- 220kV Air-Insulated Grid Substation Bay Build
- Mass AMI Smart Electricity Meter Swap Route
- 63kV Overhead Aluminum HTLS Reconductoring
- 110kV XLPE Underground Cable Splice & HiPot
- PWR Nuclear Power Plant Refueling Outage (RFO)
- 450MW Gas Turbine Hot-Gas-Path Inspection
- Electric Bus Depot 3MW Grid Transformer Upgrade
- 2GW Offshore HVDC Converter Thyristor Maintenance
- Municipal Streetlight Zhaga-D4i Smart LED Retro
- Substation IEC-61850 Protection Relay Maintenance
- Industrial Islandable Solar+Genset Microgrid