Industrial Islandable Solar+Genset Microgrid

Product family: Seamless Black-Start Control.

Flow: Microgrid PLC & Relays → PCC Static Transfer Install → Diesel Genset Governor Tie → Edge Grid-Forming Droop Tune → Unplanned Island Load-Shed → Seamless Re-Sync Utility Grid → Remote Mine & Campus Sites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Industrial Islandable Solar+Genset MicrogridSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Microgrid PLC & Relays → PCC Static Transfer Install (2,970 s) → Diesel Genset Governor Tie (3,510 s) → Edge Grid-Forming Droop Tune (4,860 s) → Unplanned Island Load-Shed (3,420 s) → Seamless Re-Sync Utility Grid (2,250 s) → Remote Mine & Campus Sites.SUPPLIERMicrogrid PLC &RelaysI1.83 d1PCC StaticTransfer InstallC/T 2,970 sI1.67 d2Diesel GensetGovernor TieC/T 3,510 sI2.17 d3Edge Grid-FormingDroop TuneC/T 4,860 sI0.83 d4Unplanned IslandLoad-ShedC/T 3,420 sI0.33 d5Seamless Re-SyncUtility GridC/T 2,250 sI0.50 dCUSTOMERRemote Mine &Campus Sites6 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. PCC Static Transfer Install2,970 s15 min96%95.8%211 (1.83 d)8
2. Diesel Genset Governor Tie3,510 s20 min93%97.6%210 (1.67 d)6
3. Edge Grid-Forming Droop Tune4,860 s30 min85%94.5%213 (2.17 d)4
4. Unplanned Island Load-Shed3,420 s12 min94%97.8%15 (0.83 d)7
5. Seamless Re-Sync Utility Grid2,250 s5 min98%99.4%12 (0.33 d)12

Key figures

Takt time
4,500 s
Lead time
7.96 d
Value-added time
17,010 s
Process cycle efficiency (PCE)
7.9%
Rolled throughput yield (RTY)
85.9%
Customer demand per day
6 cases
Line capacity per day
4 cases
Bottleneck
Edge Grid-Forming Droop Tune

Reading the bottleneck

The bottleneck is "Edge Grid-Forming Droop Tune": it can process 4 cases per day against a demand of 6 cases, so it falls short of demand by 40.5%. Once downtime and scrap are counted, its cycle time grows from 4,860 s to 6,050 s, against a takt of 4,500 s. The largest loss at this step is changeovers (30 min every 2 units), about 900 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Power Grids, Substations & Smart Metering: Power Grids, Substations & Smart Metering