63kV Overhead Aluminum HTLS Reconductoring

Product family: High-Temp Low-Sag Capacity Up.

Flow: Composite-Core Carbon Conductor → Line Outage & Earth Clamp Fit → Drone Pilot Line Puller String → Tensioner Dead-End Compress → Sag Check Laser & Spacer → Helicopter Corona Patrol & On → Regional Distribution Grids

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 63kV Overhead Aluminum HTLS ReconductoringSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Composite-Core Carbon Conductor → Line Outage & Earth Clamp Fit (1,485 s) → Drone Pilot Line Puller String (1,755 s) → Tensioner Dead-End Compress (2,430 s) → Sag Check Laser & Spacer (1,710 s) → Helicopter Corona Patrol & On (1,125 s) → Regional Distribution Grids.SUPPLIERComposite-CoreCarbonConductorI1.83 d1Line Outage &Earth Clamp FitC/T 1,485 sI1.58 d2Drone Pilot LinePuller StringC/T 1,755 sI2.17 d3TensionerDead-End CompressC/T 2,430 sI0.92 d4Sag Check Laser &SpacerC/T 1,710 sI0.42 d5Helicopter CoronaPatrol & OnC/T 1,125 sI0.50 dCUSTOMERRegionalDistribution…12 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Line Outage & Earth Clamp Fit1,485 s15 min96%95.8%422 (1.83 d)15
2. Drone Pilot Line Puller String1,755 s20 min93%97.6%519 (1.58 d)12
3. Tensioner Dead-End Compress2,430 s30 min85%94.5%426 (2.17 d)7
4. Sag Check Laser & Spacer1,710 s12 min94%97.8%211 (0.92 d)12
5. Helicopter Corona Patrol & On1,125 s5 min98%99.4%15 (0.42 d)23

Key figures

Takt time
2,250 s
Lead time
7.73 d
Value-added time
8,505 s
Process cycle efficiency (PCE)
4.1%
Rolled throughput yield (RTY)
85.9%
Customer demand per day
12 cases
Line capacity per day
7 cases
Bottleneck
Tensioner Dead-End Compress

Reading the bottleneck

The bottleneck is "Tensioner Dead-End Compress": it can process 7 cases per day against a demand of 12 cases, so it falls short of demand by 40.5%. Once downtime and scrap are counted, its cycle time grows from 2,430 s to 3,025 s, against a takt of 2,250 s. The largest loss at this step is changeovers (30 min every 4 units), about 450 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Power Grids, Substations & Smart Metering: Power Grids, Substations & Smart Metering