Direct Lithium Extraction (DLE) & Li2CO3 Plant

Product family: 99.5% Battery-Grade Carbonate.

Flow: Salars Brine Injection Wells → Raw Brine Filter & Silica Trap → DLE Ion-Sieve Adsorption Skid → Nanofiltration & RO Concentrate → Soda-Ash Crystallizer Wash → Fine Jet-Mill & 500kg Bag → EV Cathode Refineries

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Direct Lithium Extraction (DLE) & Li2CO3 PlantSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Salars Brine Injection Wells → Raw Brine Filter & Silica Trap (614 s) → DLE Ion-Sieve Adsorption Skid (921 s) → Nanofiltration & RO Concentrate (716 s) → Soda-Ash Crystallizer Wash (597 s) → Fine Jet-Mill & 500kg Bag (477 s) → EV Cathode Refineries.SUPPLIERSalars BrineInjection WellsI1.40 d1Raw Brine Filter& Silica TrapC/T 614 sI2.20 d2DLE Ion-SieveAdsorption SkidC/T 921 sI1.60 d3Nanofiltration &RO ConcentrateC/T 716 sI1.00 d4Soda-AshCrystallizer WashC/T 597 sI1.20 d5Fine Jet-Mill &500kg BagC/T 477 sI1.40 dCUSTOMEREV CathodeRefineries95 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Raw Brine Filter & Silica Trap614 s10 min92%98.8%95133 (1.40 d)119
2. DLE Ion-Sieve Adsorption Skid921 s35 min81%95.0%95209 (2.20 d)66
3. Nanofiltration & RO Concentrate716 s20 min91%97.2%76152 (1.60 d)98
4. Soda-Ash Crystallizer Wash597 s10 min95%98.4%3895 (1.00 d)124
5. Fine Jet-Mill & 500kg Bag477 s8 min97%99.4%38114 (1.20 d)161

Key figures

Takt time
853 s
Lead time
8.84 d
Value-added time
3,325 s
Process cycle efficiency (PCE)
0.46%
Rolled throughput yield (RTY)
89.2%
Customer demand per day
95 tonnes
Line capacity per day
66 tonnes
Bottleneck
DLE Ion-Sieve Adsorption Skid

Reading the bottleneck

The bottleneck is "DLE Ion-Sieve Adsorption Skid": it can process 66 tonnes per day against a demand of 95 tonnes, so it falls short of demand by 30.6%. Once downtime and scrap are counted, its cycle time grows from 921 s to 1,197 s, against a takt of 853 s. The largest loss at this step is equipment downtime (uptime 81%), about 216 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Mining, Quarries, Lithium & Refining: Mining, Quarries, Lithium & Refining