Steam Naphtha/Ethane Cracker & Olefins Sep
Product family: Polymer-Grade Ethylene Plant.
Flow: Refinery Naphtha & Ethane → 850°C Radiant Steam Cracking → Transfer-Line Quench & Scrub → 5-Stage Cracked Gas Compress → Cryo Demethanizer Fraction → 99.95% Ethylene Pipeline Out → HDPE / PP Polymer Units
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. 850°C Radiant Steam Cracking | 306 s | 20 min | 96% | 99.1% | 270 | 234 (1.30 d) | 249 |
| 2. Transfer-Line Quench & Scrub | 383 s | 35 min | 93% | 98.4% | 270 | 252 (1.40 d) | 190 |
| 3. 5-Stage Cracked Gas Compress | 482 s | 45 min | 84% | 96.4% | 180 | 360 (2.00 d) | 132 |
| 4. Cryo Demethanizer Fraction | 324 s | 10 min | 96% | 98.8% | 72 | 198 (1.10 d) | 233 |
| 5. 99.95% Ethylene Pipeline Out | 243 s | 10 min | 98% | 99.5% | 45 | 144 (0.80 d) | 315 |
Key figures
- Takt time
- 450 s
- Lead time
- 8.12 d
- Value-added time
- 1,738 s
- Process cycle efficiency (PCE)
- 0.26%
- Rolled throughput yield (RTY)
- 92.4%
- Customer demand per day
- 180 batches
- Line capacity per day
- 132 batches
- Bottleneck
- 5-Stage Cracked Gas Compress
Reading the bottleneck
The bottleneck is "5-Stage Cracked Gas Compress": it can process 132 batches per day against a demand of 180 batches, so it falls short of demand by 26.9%. Once downtime and scrap are counted, its cycle time grows from 482 s to 595 s, against a takt of 450 s. The largest loss at this step is equipment downtime (uptime 84%), about 91.8 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Oil, Gas, LNG & Refinery Turnarounds: Oil, Gas, LNG & Refinery Turnarounds
- 150kbpd Crude Desalting & Atmospheric Topping
- Base-Load Mixed-Refrigerant LNG Liquefaction Train
- 2,400-cph LPG Domestic Gas Cylinder Hydro & Fill
- Intelligent MFL Pipeline Inline Integrity Pigging
- Airport Into-Plane Jet-A1 Fuel Farm Filtration
- SBS Polymer-Modified Highway Bitumen Mill
- Hydrocracker 28-Day Refinery Major Turnaround
- 15,000-PSI Subsea / Onshore Christmas Tree Test
- Centrifugal Sour Gas Pipeline Compressor Rebuild
- 300-Bar Fast-Fill CNG / Bio-CNG Fleet Station
- Claus Thermal Sulfur Recovery & Granulation