300-Bar Fast-Fill CNG / Bio-CNG Fleet Station

Product family: Heavy Truck Gas Fueling Skids.

Flow: 4-Stage Recip Compressors → Stainless High-Pres Piping → Dryer Molecular Sieve Tower → 4-Stage Compressor Oil-Free → Dispenser Mass-Flow Calibrate → ATEX Zone-1 Soap & Gas Hold → Municipal Bus & Truck Depots

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 300-Bar Fast-Fill CNG / Bio-CNG Fleet StationSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 4-Stage Recip Compressors → Stainless High-Pres Piping (1,836 s) → Dryer Molecular Sieve Tower (2,295 s) → 4-Stage Compressor Oil-Free (2,889 s) → Dispenser Mass-Flow Calibrate (1,944 s) → ATEX Zone-1 Soap & Gas Hold (1,458 s) → Municipal Bus & Truck Depots.SUPPLIER4-Stage RecipCompressorsI1.30 d1StainlessHigh-Pres PipingC/T 1,836 sI1.40 d2Dryer MolecularSieve TowerC/T 2,295 sI2.00 d34-StageCompressor…C/T 2,889 sI1.10 d4DispenserMass-Flow…C/T 1,944 sI0.80 d5ATEX Zone-1 Soap& Gas HoldC/T 1,458 sI1.50 dCUSTOMERMunicipal Bus &Truck Depots10 / skids

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Stainless High-Pres Piping1,836 s20 min96%99.1%1513 (1.30 d)14
2. Dryer Molecular Sieve Tower2,295 s35 min93%98.4%1514 (1.40 d)10
3. 4-Stage Compressor Oil-Free2,889 s45 min84%96.4%1020 (2.00 d)7
4. Dispenser Mass-Flow Calibrate1,944 s10 min96%98.8%411 (1.10 d)12
5. ATEX Zone-1 Soap & Gas Hold1,458 s10 min98%99.5%38 (0.80 d)17

Key figures

Takt time
2,700 s
Lead time
8.49 d
Value-added time
10,422 s
Process cycle efficiency (PCE)
4.5%
Rolled throughput yield (RTY)
92.4%
Customer demand per day
10 skids
Line capacity per day
7 skids
Bottleneck
4-Stage Compressor Oil-Free

Reading the bottleneck

The bottleneck is "4-Stage Compressor Oil-Free": it can process 7 skids per day against a demand of 10 skids, so it falls short of demand by 31.9%. Once downtime and scrap are counted, its cycle time grows from 2,889 s to 3,568 s, against a takt of 2,700 s. The largest loss at this step is equipment downtime (uptime 84%), about 550 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.